Program Processing
PES/Transport Alignment
Video PID
Audio PID (Channel 1)
Audio PID (Channel 2)
PMT PID
WST PID
Allow PID Contention
MPEG Program Number
Transport Stream ID
Physical
Height
Width
Depth
Mounting
Important: SE encoders are stackable, one on top of another, within a rack, without any
spacing requirements. Place each SE encoder in a stable and level position within the
rack and ensure that all front enclosure screws are tightened to 2 ft.-lbs. If multiple SE
encoders are installed in a rack assembly, the operator may choose to have a
certification agency evaluate the condition of the rack.
Elevation(s)
Sea Level
5,000 feet Above Sea Level
10,000 feet Above Sea Level
Important: The above temperatures must be measured inside the rack. SE encoders
require sufficient ventilation and air conditioning. To ensure safe operation, proper
airflow must be maintained at all times.
Power
AC Input
Important: Reliable earthing must be maintained to ensure proper grounding for the SE
encoder. To ensure that circuits are not overloaded, read the encoder's UL power label.
If the SE encoder is connected to a power strip, rather than a branch circuit's direct
connection, use special care to ensure that the unit is properly connected.
Document Number: 504834-001
Value
Yes
32 to 8187, Default 32 (Decimal)
32 to 8190, Default 33 (Decimal)
32 to 8190, Default 34 (Decimal)
32 to 8190, Default 35 (Decimal)
32 to 8190, Default 36 (Decimal)
No
1 to 65535, Default 1 (Decimal)
0 to 65535, Default 1 (Decimal)
Rack Requirement
1.75" (1 U)
17.3"
19.8"
Rack stackable in standard 19" W x 32" D stack
Required Temperature
0 to 40° C
0 to 37° C
0 to 34° C
Description
115 – 230 VAC, 50 – 60 Hz, 1 Amp
35