DOK-MOTOR*-MSK********-PR12-EN-P
Synchronous Servomotors MSK
9
Operating conditions and application notes
9.1
Environmental conditions
9.1.1
Installation altitude and ambient temperature
The stated performance data of the motors are valid according to DIN EN
60034‑1 for:
●
Ambient temperature 0 ... 40 °C
●
Installation altitude 0 ... 1000 m above sea level
If the specified limits are exceeded, the performance data of the motors must
be reduced.
①
Utilization depending on the ambient temperature
②
Utilization depending on the installation altitude
f
Temperature utilization factor
T
t
Ambient temperature
A
f
Height utilization factor
H
h
Installation altitude in meters
Fig. 9-1:
Derating of ambient temperature, installation altitude (in operation)
Calculation of performance data in case the limits specified are exceeded:
Ambient temperature > 40 °C
M
= M
×f
0_red
0
T
Installation altitude > 1,000 m
M
= M
×f
0_red
0
H
Ambient temperature > 40 °C and setup elevation > 1,000 m
M
= M
×f
×f
0_red
0
T
H
Bosch Rexroth AG
Operating conditions and application notes