Siemens 6SN1123-1AA00-0DA2 Configuration Manual page 316

Simodrive 611 series drive converter
Table of Contents

Advertisement

05.01
Schematic diagram
Filter (X kW)
3)
F
(X A)
L
N
K
L1
L2
L3
PE
1)
L1
L2
L3
2)
Filter (X kW)
3)
F
(X A)
L
N
K
L1
L2
L3
PE
Consequences when incorrectly connected to
the line supply:
1) Another supply, e.g. UPS:
S
Defective DC link electrolytic capacitors at
the power supply
S
The following burn:
DC link de–coupling diodes
PC board tracks of the power supply
Note:
3) L
for 5 kW and 10 kW integrated, therefore not necessary here!
k
4) P500/M500 connection at X181 either loop–through at X181 or connect directly to the DC link.
Fig. 8-32
Examples for correct and prohibited three–conductor connection to the line supply + DC link connection
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
8.15 Examples of correctly and incorrectly connecting NE
Correct!
NE
e.g. NCU PMxx
X181
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1
Twisted
cable
P600
M600
U1
V1 W1
PE
Three–conductor connection
to the line supply with DC
link buffering
Incorrect!
NE
e.g. NCU PMxx
X181
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1
Twisted
cable
P600
M600
U1
V1 W1
PE
2) Another connection to the line supply in front of
8 Important Circuit Information
PMxx
MM
PMxx
4)
X181
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1
4)
PMxx
MM
PMxx
X181
M500
P500
2U1
1U1
2V1
1V1
2W1
1W1
the reactor (choke):
S
Defective DC link electrolytic capacitors at
the power supply
S
The following will burn in the power supply
Connector
De–coupling diodes
PC board tracks
Pre–charging circuit, printed circuit board
v4 MM
8
PMxx
8-315