6 Infeed Modules
6.4 Technical data
Table 6-10
Technical data, UI modules
Heat dissipation
6SN11 45-
Heat dissipation
6SN11 46-
Hose cooling
6SN11 45-
Infeed/regenerative
feedback
kW
Rated power (S1)
kW
S6 power
kW
Peak power (400 V)
Input currents (
Use for dimensioning the installation, not for calculating the power!
(AC
)
RMS
Rated current (400 V)
12
Built-in pulsed resi-
stor
Continuous power/
kW
Peak power
Energy consumption,
kWs
max:
Connection data
Voltage (power)
V
Voltage (electronics)
V
Power supply
V
Frequency
Hz
Connection cross–
mm
section, max.
Output voltage
V
Output frequency
Hz
Module width
mm
Type of cooling
Internal cooling
Internal cooling
External cooling
External cooling
Hose cooling
Hose cooling
Losses
Internal cooling
W
External cooling
W (int./ext.)
Hose cooling
W (int./ext.)
Efficiency η
Weight
Internal cooling
kg
External cooling
kg
Hose cooling
kg
6-168
–
1AB00–0BAV (INT./EXT.)
–
5
6.5
10
24
0,2/10
E = 13,5
refer to Chapter C.1.3, Table 3.5
refer to Chapter C.1.3, Table 3.5
At DC link with 600/625/680 V DC or parallel infeed, AC and DC connection
50 to 60 10%
2
6
0...490...680 depending on the line supply voltage
0...1400 depending on the control unit
50
Non–ventilated
Non–ventilated
Non–ventilated
Non–ventilated
–
–
270
270/–
–
0.98
6.5
6.5
–
Note
Temperature derating, see Chapter 5.4.2.
Installation altitude derating, see Chapter 5.4.3.
1AA01–0AAV (INT./EXT.)
–
–
10
13
25
68
0,3/25
E = 7,5
16
100
Universal cooling
Universal cooling
internal/external
internal/external
–
–
450
120/330
–
0.98
9.5
9.5
–
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
05.08
02.12
05.01
1AA00–0CAV (INT.)
1AB00–0CAV (EXT.)
–
28
36
50
–
–
50
200
Internal separately–
Internal separately–
driven fan
driven fan
Integrated third–party
Integrated third–party
fan (volumetric flow,
fan (volumetric flow,
3
both 42 m
/hr)
250
90/160
–
0.98
15.5
15.5
–