Removal
1. Park machine on a level surface, lower cutting deck,
stop engine, engage parking brake, and remove key
from the ignition switch.
2. Remove hood using Figure 5 as a guide.
Installation
1. Install hood using Figure 5 as a guide.
2. Align hood to machine to allow correct operation of
hood latches and dust seals:
A. Place shim that is 3/8" to 7/16" (9.5 to 11.1 mm)
thick on top of frame (both RH and LH sides) near the
sides of oil cooler (Figs. 6 and 7).
B. Close hood so that it rests on shims and fasten
the hood latches.
C. Loosen hood pivots at frame to adjust vertical
placement of pivots. Re−tighten hood pivot fasten-
ers.
D. Loosen pivot brackets to allow hood latches to
pull hood against radiator support. Re−tighten pivot
bracket fasteners.
3. After hood is assembled to machine, check for the
following:
A. Check that bulb seals are equally compressed at
all contact points with hood.
B. Hood should open and close without contacting
oil cooler hardware.
Groundsmaster 4100−D
1. LH shim location
2. LH hood pivot
3
2
1. RH shim location
2. RH hood pivot
Page 7 − 7
3
2
1
Figure 6
3. LH pivot bracket
1
Figure 7
3. RH pivot bracket