3.7

Clearances during setup

A
H
1200
2000
B
H
1200
2000
2000
Fig. 7
Clearances during setup
[*]
The clearance can be reduced on one side. This may however lead
to a higher noise level.
[A]
Installation clearances of heat pump.
[B]
Installation clearances of heat pump with sound insulation
(accessory).
4

Preparing for installation

4.1

Installation locations

▶ Set up the heat pump outdoors on a flat stable surface.
▶ When setting up the heat pump, make sure it can be accessed at all
times in order to carry out maintenance work. If access is restricted,
e.g. due to the ceiling height, suitable measures must be taken to
ensure that maintenance work can still be carried out without
additional time expenditure or costly assembly aids.
▶ Bear in mind the sound propagation of the heat pump when setting it
up, particularly in view of avoiding a noise nuisance to neighbours.
▶ Whenever possible, do not set up the heat pump in front of rooms
sensitive to noise.
Compress 7000i AW – 6721830633 (2021/02)
2000
2000
800)
400
2000
800)
700
H
1200
2000
500)
H
1200
2000
2000
500)
▶ Do not set up the heat pump in a corner where it is flanked by walls on
3 sides. This can increase the noise level and soiling of the
evaporator.
Fig. 8
Avoid setting up in locations surrounded by walls
Preparing for installation
2000
2000
400
2000
700
7