    Table of contents Connection option for the IP module ....21 Table of contents Information on refrigerant..... . . 22 Explanation of symbols and safety instructions .
  • Page 3: Explanation Of Symbols And Safety Instructions

    Explanation of symbols and safety instructions understand the resulting dangers. Children shall not Explanation of symbols and safety instructions play with the appliance. Cleaning and user maintenance must not be performed by children Explanation of symbols without supervision.” Warnings “If the power cable is damaged, it must be replaced by In warnings, signal words at the beginning of a warning are used to indicate the type and seriousness of the ensuing risk if measures for the manufacturer, its customer service department or...
  • Page 4: Product Description

    EU legislation, which is stipulated by attaching this marking. The complete text of the Declaration of Conformity is available on the Internet: worcester-bosch.co.uk. Heat pump (outdoor unit) The heat pump is inverter operated, which means that it will automatically change the compressor speed to deliver the exact amount of energy required at the moment.
  • Page 5: Generic Overview Of The Refrigerant Circuit

    Product description 2.3.2 Generic overview of the refrigerant circuit 75 % 100 % 25 % +2 °C –2 °C +27 °C +35 °C 0 °C 88 °C –4,5 °C 50 °C Fig. 2 Functional principle of the refrigerant circuit in the heat pump This booster heater is integrated, an its on/off is controlled by the user interface in the indoor unit.
  • Page 6: Operation

    Operation • Do not set a too low temperature for cooling. Cooling will also The adjustment ranges, default settings and functional scope may differ consume energy. from the information in these instructions, depending on the system installed at the site. Vent the room correctly •...
  • Page 7: Switching Off

    Operation Item Symbol Explanation Solar circulation pump is in operation. The standard display refers only to the displayed heating circuit. Changing the required room temperature in the standard display only DHW heating is active affects the heating circuit displayed. DHW thermal disinfection active Item Symbol Explanation Extra DHW active...
  • Page 8: Selecting A Heating Circuit For The Standard Display

    Operation ▶ To switch on the system: ▶ Press and hold the d key to return to the standard display. – Press and hold the selector until a pop-up menu is displayed. – Select Yes in the menu Switch from standby mode to normal operation? After a prolonged power failure or extended period of idleness, the date and time may need to be reset.
  • Page 9: Adapting The Heating System Settings Using The Time Program (Automatic Mode)

    Operation Automatic mode ▶ Set and confirm the switching time. ▶ Open the Heating or Heating/Cooling > Temperature settings > Heating, Setback or Cooling menu. 0010010089-001 Adjusting the temperature/operating mode for a time slot 6 720 811 136-07.1O ▶ Open the menu for adapting a time program for the heating system. ▶...
  • Page 10: Selecting Active Time Program For The Heating

    Operation ▶ Select days (e.g. Monday and Tuesday) that are to be overwritten ▶ Open Heating or Heating/Cooling > Time program > Heating with the previously selected time program and confirm. circuit 1 > Rename heating circuit menu (or other heating circuit). 0010004419.001 0010008233-001 The cursor flashes to indicate the start position for data input.
  • Page 11: 3.2.10 Dhw Settings

    Operation 3.2.10 DHW settings ▶ Select Own time program and confirm. ▶ Set switching times and operation modes. When the thermal disinfection function is activated, the DHW cylinder is heated to the corresponding temperature set. The higher temperature hot water can be used for thermal disinfection of the hot water system. ▶...
  • Page 12: 3.2.12 More Settings

    Operation ▶ Select and confirm the heating circuits and DHW systems. 3.2.12 More settings Setting the time and date If the user interface has been disconnected from the power supply for a prolonged period, the date and time must be set: ▶...
  • Page 13: Main Menu

    Operation Main menu Setting the summer/winter switchover threshold Depending on the heating appliance and how the user interface is used, CAUTION not all menu items will be available for selection; see overview of main Risk of system damage! menu at the end of this document. ▶...
  • Page 14: Dhw Settings

    Operation 3.3.2 DHW settings Table 9 Settings for the extra hot water function Thermal disinfection Using the extra DHW, thermal disinfection or daily heat up functions can WARNING lead to higher electricity cost as the electric booster heater may be Danger to life from legionella! activated.
  • Page 15: Settings For The Venting Function

    Operation Setting the DHW alternating operation Menu item Description If DHW alternating operation is not activated, DHW heating has priority Air quality [Setting the desired air quality level: and interrupts the heat requirement of the heating system, if necessary. • [Adequate] Menu: DHW alternating operation •...
  • Page 16: Settings For Other Systems Or Devices

    Operation Menu: PV system Menu item Description DHW settings for the selected DHW systems during Menu item Control range: Function description the holiday period. Heating peak The energy available in the PV system is used for heating, if • If [Off] is set, no DHW at all will be available the system is in heating mode.
  • Page 17: Calling Up Information About The System

    Operation Menu: DHW Menu item Description Warning sound If a buzzer has been installed a warning sound is Menu item Description blocked emitted as soon as an alarm occurs. The warning Set temp. Desired DHW temperature. sound can be suppressed at a settable time interval. Measured temp.
  • Page 18: Faults

    Maintenance Menu: Energy consump. Menu: Outdoor temp The currently measured outside temperature is displayed in this menu. In Menu item Description addition, a diagram of the outside temperature profile for today and Total Cumulated total energy consumed by the heating yesterday (from 00:00 to 24:00 in each case) is displayed here.
  • Page 19: Check System Pressure

    Maintenance 6 720 805 915-01.1I Fig. 7 Cleaning the strainer ▶ Screw the cap back on (tighten handtight). ▶ Open the valve (4). Check the magnetite indicator After installation and startup the magnetite indicator must be checked at more frequent intervals. If a lot of magnetic dirt is clinging to the magnetic bar in the particulate filter and that dirt frequently causes an alarm related to the poor flow (e.g., low or poor flow, high flow supply or HP alarm) an approved magnetite filter must be installed to avoid regular...
  • Page 20: Moisture In Cooling Mode

    Maintenance 4.1.5 Moisture in cooling mode NOTICE In some regions, washing-up liquid must not be flushed into gravel beds. Insufficient condensate insulation If the condensate tube discharges into a gravel bed: Moist near the components of the heating system. ▶ Remove the flexible condensate tube from the drain pipe prior to cleaning.
  • Page 21: Connection Option For The Ip Module

    Connection option for the IP module with a free RJ45 output are necessary. This can lead to additional costs. The Bosch HomeCom Easy app is required to control the system using a mobile phone. The IP module is installed as standard in a number of products and can The IP module can be used to control and monitor the system via a mobile be retrofitted to others as an accessory.
  • Page 22: Information On Refrigerant

    Internet, and the IP module software is not automatically Alternately, the password can be changed at the control device. updated. • App Bosch HomeCom Easy Login data for the IP module When starting the app for the first time, you will be asked to enter the Manuf.
  • Page 23: Environmental Protection And Disposal

    Data Protection Officer, Information Security and Privacy (C/ISP), The 3-way valve distributes thermal energy to the heating circuits or the Robert Bosch GmbH, Postfach 30 02 20, 70442 Stuttgart, GERMANY. DHW cylinder. It has two defined settings so that heating and DHW...
  • Page 24 Technical terms heating cannot occur at the same time. This is also the most effective Desired room temperature operating mode, as the DHW is always heated to a specific temperature, The room temperature to be achieved by the heating system. It can be set while the heating water temperature is continuously adjusted to the individually.
  • Page 25: Overview Main Menu

    Overview Main menu – Humidity Overview Main menu – Air quality This is an overview of all possible menu items. In each installation only – Bypass menus of installed modules or components are shown. – Supply air temp. control – Reheat supp.air temp. (After-heater supply air temperature) Heating or Heating/Cooling –...
  • Page 26: Overview Info

    Overview Info – Min. outside temp. – DHW – Reset – Pool – Reset settings – Compressor – Total – Heating – DHW Overview Info – Cooling This is an overview of all possible information. In each installation only – Pool information of installed modules or components are shown.
  • Page 27 Overview Info – ESC block – PV system – Smart grid – Current operation – COP heat source Compress 7001i/7400i AW AWE – 6721835320 (2021/09)
  • Page 28 CONTROLS AND CONNECTIVITY TEAM: 0330 123 3641 APPOINTMENTS: 0330 123 9339 SPARES: 0330 123 9779 LITERATURE: 0330 123 9119 TRAINING: 0330 123 0166 SALES: 0330 123 9669 Bosch Thermotechnology Ltd. Cotswold Way, Warndon Worcester WR4 9SW United Kingdom Tel. 0330 123 9559 worcester-bosch.co.uk...