Piping Extension Beyond Flare Form - Beko BEHPI 090 Installation Manual

Split-type room air conditioner
Hide thumbs Also See for BEHPI 090:
Table of Contents

Advertisement

Available languages

Available languages

7
Refr gerant p p ng connect on
3. Place flare nuts on both ends of p pe. Make sure they are fac ng n the r ght d rect on, because you
can't put them on or change the r d rect on after flar ng. See F g. 7.3.
4. Remove PVC tape from ends of p pe when ready to perform flar ng work.
5. Clamp flare form on the end of the p pe. The end of the p pe must extend beyond the edge of the
flare form n accordance w th the d mens ons shown n the table below.
Outer d ameter of p pe (mm)
Ø 6.35 (Ø 0.25")
Ø 9.52 ( Ø 0.375")
Ø 12.7 ( Ø 0.5")
Ø 16 ( Ø 0.63")
Spl t-type room a r cond t oner / Installat on Manual
Flare nut
Copper p pe
F g. 7.3
F g. 7.4
P p ng extens on beyond flare form
M n.
0.7 (0.0275")
1.0 (0.04")
1.0 (0.04")
2.0 (0.078")
A (mm)
Max.
1.3 (0.05")
1.6 (0.063")
1.8 (0.07")
2.2 (0.086")
39 / 120 EN