Prepare Refrigerant Piping - Beko BEHPI 090 Installation Manual

Split-type room air conditioner
Hide thumbs Also See for BEHPI 090:
Table of Contents

Advertisement

Available languages

Available languages

5
Indoor un t nstallat on
Step 4: Prepare refr gerant p p ng
The refr gerant p p ng s ns de an nsulat ng sleeve attached to the back of the un t. You must prepare
the p p ng before pass ng t through the hole n the wall. Refer to the Refr gerant P p ng Connect on
sect on of th s manual for deta led nstruct ons on p pe flar ng and flare torque requ rements,
techn que, etc.
1. Based on the pos t on of the wall hole relat ve to the mount ng plate, choose the s de from wh ch
the p p ng w ll ex t the un t.
2. If the wall hole s beh nd the un t, keep the knock-out panel n place. If the wall hole s to the s de of
the ndoor un t, remove the plast c knock-out panel from that s de of the un t. (See F g. 5.3 ). Th s
w ll create a slot through wh ch your p p ng can ex t the un t. Use needle nose pl ers f the plast c
panel s too d ff cult to remove by hand.
18 / 120 EN
138mm (5.45 n)
34mm (1.35 n)
219mm (8.6 n)
76mm(3 n)
53.5mm
(2.1 n)
Left rear wall hole
174.3mm (6.85 n)
65mm (2.5 n)
1080mm (42.5 n)
389mm (15.3 n)
172mm (6.8 n)
52mm (2.05 n)
Left rear wall hole
65mm (2.5 n)
1259mm (49.55 n)
Spl t-type room a r cond t oner / Installat on Manual
517.4mm (20.37 n)
144mm (5.65 n)
Indoor un t outl ne
R ght rear wall hole
65mm (2.5 n)
965mm (38 n)
Model C
553mm (21.77 n)
300mm (11.8 n)
53.5mm (2.1 n)
148.7mm
(5.85 n)
Indoor un t outl ne
47mm (1.85 n)
R ght rear wall hole
65mm (2.5 n)
151mm (5.95 n)
Model D
643.6mm (25.3 n)
257mm (10.1 n)
332mm (13.05 n)
Indoor un t outl ne
52mm (2.05 n)
R ght rear wall hole
65mm (2.5 n)
Model E