Electrical System Quick Check - Toro Reelmaster 5200-D Service Manual

Hide thumbs Also See for Reelmaster 5200-D:
Table of Contents

Advertisement

Electrical System Quick Check

Battery Test (Open Circuit Test)
Use a multimeter to measure the voltage between the
battery terminals.
Set multimeter to the DC volts setting. The battery
should be at a temperature of 60 to 100_ F (16 to 38_ C).
The ignition key should be off and all accessories turned
off. Connect the positive (+) meter lead to the positive
battery post and the negative (-) meter lead the the neg-
ative battery post.
NOTE: This test provides a relative condition of the bat-
tery. Load testing of the battery will provide additional
and more accurate information.
Electrical Systems
Voltage Measured
12.68 V (or higher)
12.45 V
12.24 V
12.06 V
11.89 V
Page 5 - 14
Battery Charge Level
Fully charged (100%)
75% charged
50% charged
25% charged
0% charged