Installing The Vg4-A-9543 Pipe Mount - Bosch AUTODOME IP starlight 7000i Installation Manual

Hide thumbs Also See for AUTODOME IP starlight 7000i:
Table of Contents

Advertisement

46
en | Installing the Roof Parapet and Pipe Mounts
Notice!
i
After all wiring is complete, close the cover door and tighten the two (2) captive screws on
the cover door to 10-12 N-m (90-105 in.-lbs) to ensure the Power Supply Box is watertight.
10.4

Installing the VG4-A-9543 Pipe Mount

This section details the installation steps for the VG4-A-9543 Pipe Mount. If you are installing
the Roof Parapet mount, refer to Installing the VG4-ROOF-MOUNT for instructions.
Notice!
Customer must supply 1-1/2 inch (NPS) pipe threaded on both ends with a minimum length
i
of 5 inches (12.7 cm).
You must use Teflon tape for thread-sealing compound.
All screws shall be tightened securely.
Figure 10.5: Pipe Mount
1
2
3
1.
2.
Notice!
i
Each fastener must have a minimum pullout strength of 275 kg (600 lbs). The mounting
material must be able to withstand this pull-out force. For example, 19-mm (3/4-inch)
minimum for plywood.
3.
Warning!
You must thread the pipe onto the Top-mounting Flange until it is tight. Failure to do so can
!
result in damage, serious injury or death.
4.
5.
2021-03 | 1.2 |
5 in.
min.
12.7 cm
Before installing the Top-Mounting Flange, ensure there is an adequate opening in the
ceiling or mounting structure for the wires to pass through.
Secure the pipe Flange with supplied gasket to the ceiling or other supporting structure
using four (4) 10-mm (3/8-inch) diameter fasteners.
Attach pipe (not supplied) to the Top-mounting Flange.
Route the power, video, control, and alarm wires through the Top-Mounting Flange and
down the pipe.
Wrap at least five layers of Teflon tape around the threads.
Gasket
Flange
Cap
Installation Manual
AUTODOME IP starlight 7000i
Bosch Security Systems

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents