Single Slot USB/Serial Cradle

Troubleshooting the Single Slot USB/Serial Cradle
Table 7-3
Symptom
LEDs do not light
when FR6874 or
spare battery is
inserted.
Troubleshooting the Single Slot USB/Serial Cradle (Continued)
Table 7-3
Symptom
FR6874 battery is
not charging.
Spare battery is not
charging.
During data
communication, no
data transmits, or
transmitted data was
incomplete.
 
Possible Cause
Cradle is not
Ensure the power cable is connected securely to both the cradle
receiving power.
and to AC power.
FR6874 is not
Remove and re-insert the FR6874 into the cradle, ensuring it is
seated firmly in the
firmly seated.
cradle
Spare battery is not
Remove and re-insert the spare battery into the charging slot,
seated firmly in the
ensuring it is firmly seated.
cradle.
Possible Cause
FR6874 was
Ensure cradle is receiving power. Ensure FR6874 is seated
removed from
correctly. Confirm main battery is charging under
cradle or
System
cradle was
six hours.
unplugged from AC
power too soon
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty
battery.
The FR6874 is
Remove and re-insert the FR6874 into the cradle, ensuring it is
not fully seated in
firmly seated.
the cradle.
Ambient
Move the cradle to an area where the ambient temperature is
temperature of the
between 0°C (32°F) and 35°C (95°F).
cradle is too warm.
Extreme battery
Battery does not charge if ambient temperature is below 0°C (32°F)
temperature.
or above 45°C (113°F).
Battery not fully
Remove and re-insert the spare battery in the cradle, ensuring it is
seated in charging
firmly seated.
slot.
Battery inserted
Re-insert the battery so the charging contacts on the battery align
incorrectly.
with the contacts on the cradle.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty
battery.
Ambient
Move the cradle to an area where the ambient temperature is
temperature of the
between 0°C (32°F) and 35°C (95°F).
cradle is too warm.
FR6874 removed
Replace FR6874 in cradle and retransmit.
from cradle during
communications.
Incorrect cable
See the system administrator.
configuration.
Maintenance & Troubleshooting