Philips Fisio 311 Service Manual page 21

Hide thumbs Also See for Fisio 311:
Table of Contents

Advertisement

Départ. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
b) Check Current_ON
- Turn the mobile on.
When the mobile is ON (backlight activated) the current measured must be :
c) Check Current_maximum
- Press on OK to activate Page selection. Press the Key 1 and then OK to select Page 1
- Press on Key 4 to select Antenna test. Press on the left arrowhead of the Compass Key as much times as
necessary to reach level 5.
When the mobile is emitting (backlight ON) the current measured must be :
- Remove the battery.
- Gently slide the card out away from the Product
© PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
This measurement has to be operated during first seconds after switch on.
(The mobile is now set at his maximum emission level)
COMPANY RESTRICTED
VY-V-640-204
Page : 21 of 42
Langue : EN
Date : 09/21/01
100 < I (mA) < 150
270 < I (mA) < 370
VY-V-640-204

Advertisement

Table of Contents
loading