8.3

Battery Charging (IGN : Ignition) / Current Consumption

8.3.1
Charger detection / Battery charging
- Plug the transformer unit into an easily accessible AC power socket.
- Insert the Test production Card in the mobile, plug a reference Battery with a multimeter added (see picture) for
current measurement.
- Plug the connector of the charger into the right socket at the base of the transceiver
The battery symbol should indicate the state of charge :
Bars moving
Steady
If the battery is totally discharged, the battery icon will start scrolling 2 to 3 minutes only after being connected to
charger.
After few seconds a charge current of 400 < I (mA) < 600 have to be observed
- Unplug the charger
8.3.2
Current consumption
a) Check current_OFF :
When the mobile is OFF the current measured must be : 0.05 < I (mA) < 0.23
© PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
- means the battery is being charged.
- means the battery is fully charged.