TEST PROCEDURES

8.1

Initial Functional Check for Fisio 311

8.1.1
Insert the Test Production Card into the SIM Reader at the back of the cellular phone and clip a charged
battery on the phone.
8.1.2
Press the «ON» button for 2 seconds at least and the LCD will show a message which contains information
of FA (Final Adjustment) status and 12NC.
8.1.3
Follow the instructions as mentioned below :
Step
Procedure
Press Key 1
1
Press Key 1 again.
Press key 2
(Audio loop local effect)
2
Press key 2 again
Press key 3
Audio loop test (Speak to Mic
and listen echo from Speaker)
3
Press key 3 again
Press key 4
Check for the Backlight
function in the same time.
4
Press key 4 again
Press Key 5
(Checkerboard test)
5
Press Key 5 again
Press Key 6
(Inverted Checkerboard)
6
Press Key 6 again
© PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
Observation
Continue Buzzer signal
Left corner displays 1
"LocalEffect"
" XX XX XX"
" XX XX"
Left corner displays 2
"AUDIO xx xx xx xx"
"EEP xx xx xxxx "
Left corner displays 3
Backlight must be on
Left corner displays 4
Checkerboard 1 pixel on
Left corner displays 5
Checkerboard 2 pixel on
Left corner displays 6
COMPANY RESTRICTED
VY-V-640-204
Page : 13 of 42
Langue : EN
Date : 09/21/01
00
01
02
03
04
05