11. Troubleshooting

Touching the current-carrying parts may cause a fatal electric shock or burn
injury.
To prevent a physical accident, such as an electric shock, burn injury, etc., make sure
to observe the followings.
Only educated and/or skilled persons who well understand the welding power source should perform trouble-
shooting work.
Make sure to turn off power switches of this unit, distribution box and all other related devices for safety reasons
before taking any actions for correcting an error.
As for the inside inspection, make it at least 5 minutes after turning the power off in consideration of electric dis-
charge from a capacitor.
When the power switch is turned off automatically, contact sales distributor or Panasonic rep-
resentatives without turning it on again.
The power switch uses a non-fuse circuit breaker. If over-current occurs for some reasons,
the power is turned off automatically (tripping). Do not turn it on again.
(It is ous to turn the power on again without removing the cause of such over-current.)
Notice
Do not turn the power on with the top panel and/or side panel of this product removed.
The electromagnetic force may cause troubles (deformation, mechanical contact, etc.) to the inside devices and parts,
and may break them and/or affect their functions and performance.

11.1 Error codes and messages

This product is designed to indicate an error status on
the displays ((1) to (3) in the figure on the right) on the
front panel when an self-diagnosable error occurred.
The error codes and status are shown in the following
table.
In the case of welding errors that are not covered in the
following table, see "Troubleshooting" table.
(1)
(2)
E r r
Code
Message
E r r
-01
EmergencyStop
E r r
-02
Sec. OverCurrent
E r r
-03
Temp. Over Error
OMCTT5621E18
WARNING
CAUTION
(3)
An emergency stop signal was input from external equipment connected to
the jig terminal.
• Turn off the power switch of this product, remove the causes of the emergency
stop signal of the external equipment, and then turn the power on.
It may be failure of this product.
Please contact sales distributor or Panasonic representative.
The temperature inside this product has been increased.
• Do not turn the power off until the temperature inside this product is reduced.
(When the inside is cooled down, such error indication disappears automati-
cally.)
• Remove the causes of such temperature increase (excessive usage ratio, the
presence of foreign substances near the side ventilator and/or the rear air inlet,
etc.).
Troubleshooting
(3)
(1)
(2)
Remedy