3. Installation

3.1 Installation siter

This product is designed for indoor use only.
Do not install it in any places subject to rain or water spray.
Do not use this product in a vertical position (i.e.: with its control panel side up).
Using it in the vertical position may reduce its cooling effect, and cause any troubles like equip-
ment burnout, etc. Therefore, make sure to use it in the horizontal position (in the proper posi-
tion).
Indoors, not subject to direct sunlight or rain, with less
moisture and dust in industrial environment area.
Ambient temperature: -10°C to 40°C
Maintain an appropriate distance of 20 cm or more from
any wall or other devices.
Maintain an appropriate distance of 30 cm or more
between power sources installed side-by-side.
(Install this product in the horizontal position.)
Places where the welding arc area is not subject to wind.
(Protect the area from wind by a partition, etc.)
Places where the product is not likely to take in metallic
foreign substances

3.2 Power supply equipment

Observe the following to prevent burnout, destruction of parts and unstable arc.
Input voltage
Input current
Input protective devices
(Breaker, fuse etc.)
Cable cross section area
for input cable and ground wire
Note
• This Class A equipment is not intended for use in resi-
dential locations where the electrical power is provided
by the public low-voltage supply system. There can be
potential difficulties in ensuring electromagnetic compati-
bility in those locations, due to conducted as well as radi-
ated radio-frequency disturbances.
10
CAUTION
CAUTION
Note
When the product, which is installed on the floor, is too low to
operate, customers are required to prepare a table to mount
it. (And, in that case, provide such a table with a flange, etc. so that
the product does not slip down from the table.)
CAUTION
400 VAC
15 A
Type and capacity to be applied should conform to all national and
local codes.
Type and size of cables to be applied should conform to all national
and local codes.
• This equipment does not comply with IEC 61000-3-12. If
it is connected to a public low voltage system, it is the
responsibility of the installer or user of the equipment to
ensure, by consultation with the distribution network
operator, that the equipment may be connected.