Refrigerant Tank Scale Calibration Check - Bosch ACS 651 Original Instructions Manual

A/c service unit
Hide thumbs Also See for ACS 651:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 67
en
86 | ACS 651/751 | Commissioning
4.6
Refrigerant tank scale calibration
check
The refrigerant tank scale is calibrated at the factory.
You can perform a calibration check to determine the
accuracy of the R134a scale.
i
Before performing the calibration check, ensure
that the ACS 651/751 is positioned on a horizontal,
vibration-free surface.
1. In the main menu select "ACS
2. Select "Maintenance" → "R134a Calibration
Check".
3. Select "Start Calibration
4. Attach the calibrating weight (Fig. 24, Pos. 2) to the
neck (Fig. 24, Pos. 1) of the R134a cylinder.
1
Fig. 24:
Attaching the standard calibrating weight to the cylinder
neck
i
The part number of the weight is F 002 DG3 4RD.
5. Select "Place Standard Weight".
6. The option "Calibration Check" is automatically
selected.
|
1 689 988 238
2012-11-06
Maintenance".
Check".
2
i
Calibration Check OK
If the message
played, the calibration check is complete and the refrig-
erant tank cylinder does not require calibration.
7. Press E.
8. Press c thrice to return to the main menu.
"
You have successfully checked if the refrigerant tank
scale is accurate.
i
Calibration Check NOK
If the message
played, the refrigerant tank sensor has to be calibrat-
ed. Contact customer service to perform calibration.
is dis-
is dis-
Robert Bosch GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs 751

Table of Contents