To provide the adhesive with a closed substrate, the surface intended for the installation of the sensor base should be
free of any gaps or misalignment (see Figure 4 Available parking space for sensor installation). This is crucial for the
contact surface and the adhesive effect of the sensor.
Figure 5 Substrate example (continuous)

Installation of the sensor base

The bottom of the base has been processed with a plasma treatment for the adhesion of the glue
on the ground:
⇒ Take out the base of the sensor only just before putting down the glue there.
⇒ Do not touch the bottom side of the base with your hands or anything else.
⇒ Do not put the base on the ground before gluing, to avoid dust on the sensor base.
⇒ Ensure that all parts of the sensor device will be protected and will be kept clean till the installation
has been completed, so that these parts will be used only within the described intended use.
⇒ Check that the glue is compatible with the ground and the base of the sensor.
Insert the adhesive cartridge into the glue gun/adhesive press (Fig. 7 Inserting the adhesive cartridge; in the case of
DELO®-PUR 9692, the mixing ratio is 1:1, so you do not have to pay attention to the orientation of the cartridge). Then
attach the mixing tube on the cartridge by removing the cartridge cap (Fig. 8 Sealing cap adhesive cartridge) and
attaching the mixing tube (Fig. 9 Mixing tube on adhesive cartridge; here, bayonet fitting).
© Bosch Connected Devices and Solutions GmbH 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing,
distribution, as well as in the event of application for industrial property rights.
Figure 6 Substrate example (gap)
Warning
6 | 18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tps110

Table of Contents