Error Message
B301
Expansion ROM not
initialized – Mezzanine
Slot 1
B302
Expansion ROM not
initialized – Mezzanine
Slot 2
B303
Expansion ROM not initialized
– Mezzanine Slot 3
B304
Expansion ROM not initialized
– Mezzanine Slot 4
B30A
Expansion ROM not initialized
– I/O Blade PCI Slot
B311
IOV-SW Module 1 Slot 1
B312
IOV-SW Module 1 Slot 2
B313
IOV-SW Module 1 Slot 3
B314
IOV-SW Module 1 Slot 4
B321
IOV-SW Module 2 Slot 1
B322
IOV-SW Module 2 Slot 2
B323
IOV-SW Module 2 Slot 3
B324
IOV-SW Module 2 Slot 4
B022
Serial Port Configuration
Overlapped.
B030
PCI System Error on
Bus/Device/Function
B040
PCI Parity Error on
Bus/Device/Function
C010
The error occurred during
temperature sensor reading
C011
System Temperature out of the
range.
C020
The error occurred during
voltage sensor reading.
C021
System Voltage out of the
range.
C040
SROM data read error
st
C061
1
SMBus device Error
detected.
nd
C062
2
SMBus device Error
detected.
rd
C063
3
SMBus device Error
detected.
th
C064
4
SMBus device Error
detected.
th
C065
5
SMBus device Error
detected.
138
Cause
Failed to expand option ROM of
Mezzanine slot 1.
Failed to expand option ROM of
Mezzanine slot 2.
Failed to expand option ROM of
Mezzanine slot 3.
Failed to expand option ROM of
Mezzanine slot 4.
Failed to expand option ROM of I/O
Blade PCI slot.
Failed to expand option ROM of
IOV-SW Module 1 slot 1.
Failed to expand option ROM of
IOV-SW Module 1 slot 2.
Failed to expand option ROM of
IOV-SW Module 1 slot 3.
Failed to expand option ROM of
IOV-SW Module 1 slot 4.
Failed to expand option ROM of
IOV-SW Module 2 slot 1.
Failed to expand option ROM of
IOV-SW Module 2 slot 2.
Failed to expand option ROM of
IOV-SW Module 2 slot 3.
Failed to expand option ROM of
IOV-SW Module 2 slot 4.
Overlapping serial port
configuration was detected.
PCI SERR was detected.
PCI PERR was detected.
An error occurred while reading the
temperature sensor.
A temperature abnormality was
detected.
An error occurred while reading the
voltage sensor.
A system voltage abnormality was
detected.
SROM data reading error
st
An error occurred in the 1
SM Bus.
nd
An error occurred in the 2
SM
Bus.
rd
An error occurred in the 3
SM
Bus.
th
An error occurred in the 4
SM
Bus.
th
An error occurred in the 5
SM
Bus.
Express5800/B120e-h Maintenance Guide
1. POST Error Message
Solution
Disable expansion of option ROM of the
board that is not used for OS boot.
Disable expansion of option ROM of the
board that is not used for OS boot.
Run SETUP, select Advanced → Serial
Port Configuration, and specify the setting
again in a way that the values of Base I/O
or Interrupt in Serial Port A and Serial Port
B will not be the same.
Contact your sales representative.
It is possible that a fan has failed or is
clogged. Contact your sales representative.
Contact your sales representative.