Electrolux EWM09312 Service Manual page 55

Hide thumbs Also See for EWM09312:
Table of Contents

Advertisement

E6A
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
E6H: Heating element power relay faulty (incongruence between
E6H
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J6-1/J6-2 and the
appliance body.
-(see Fig. 6)-
Is the circuit open?
YES
Replace the main circuit
board and repeat the
diagnostic cycle to check for
any further alarms.
Fig. 15
Technical Support - A.D.L.
E6A: Heating relay sensing faulty
sensing and relay status)
Detach the connector
and measure between
the heating element
and the earth contact.
NO
- (see Fig. 15)-
Is the circuit
open?
YES
Check/replace the wiring and repeat the diagnostic cycle to
General earthing
connection
Washing heating
element
Fig. 6
!
Check that all the connectors are correctly inserted
If there are burns on the circuit board,
!
Run phase 8 of the diagnostic
cycle, drain water from the tub.
NO
and repeat the diagnostic cycle
to check for any further alarms.
check for any further alarms.
If there are burns on the circuit board,
!
55/70
E6A
see page 68
E6H
Replace the heating element
MAIN CIRCUIT
BOARD
see page 68
599 74 23-12 Rev.00

Advertisement

Table of Contents
loading

Table of Contents