E68
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J6-1/J6-2 and the
appliance body.
-(see Fig. 6)-
Is the circuit open?
YES
Replace the main circuit
board and repeat the
diagnostic cycle to check for
any further alarms.
Fig. 15
Technical Support - A.D.L.
E68: Washing heating element leakage
Detach the connector
and measure between
the heating element
and the earth contact.
NO
- (see Fig. 15)-
Is the circuit
Check/replace the wiring and repeat the diagnostic cycle to
Fig. 6
General earthing
connection
Washing heating
element
!
Check that all the connectors are correctly inserted
NO
open?
YES
check for any further alarms.
Fig. 4
If there are burns on the circuit board,
!
53/70
Run phase 8 of the
diagnostic cycle, drain water
from the tub. Replace the
heating element and repeat
the diagnostic cycle to
check for any further alarms.
MAIN CIRCUIT
BOARD
see page 68