Bosch CL300 Manual page 103

Hide thumbs Also See for CL300:
Table of Contents

Advertisement

Flexible Automation
Protection
Simultaneity
Ambient
Temperature
The outputs are protected against:
Polarity reversal (24 V DC)
D
Short−circuit
D
Overload.
D
In all these cases, the LED error indicator lights. In case of a short−circuit
or overload the respective output is deactivated. After 2 ms the output is
reactivated. If the short−circuit is still present, the output is deactivated
again after 40 ms. This process is repeated after 2 ms.
The following table shows that the simultaneity factor when driving the
outputs is dependent on ambient temperature and on the use of a fan
unit.
Simultaneity Factor
Without
Fan
20 C _
80 %
55 C _
50 %
EG
GG
Fig. 4−25 Simultaneity
System Modules
With Fan in
With Fan in
the Basic Unit
the Card Cage
100 %
100 %
70 %
100 %
EG
EG
Fan
GG
GG
Fan
Fan
4−51