Walk Testing - Bosch RADION B810 Installation Manual

Hide thumbs Also See for RADION B810:
Table of Contents

Advertisement

RADION receiver SD
Frequency
Tab. 8.12: Specifications
8.1

Walk testing

Perform a walk test to determine the boundaries of the coverage
area.
Insert a slotted screwdriver into the designated hole to open the
cover and then close the detector cover to start a 90-sec Walk
Test mode.
During this test mode, motion detected within the detector's
coverage area causes a transmitted alarm and LED activation.
Each alarm will also extend the Test Mode. Adjust as necessary.
Notice!
Excessive use of the Walk Test Mode may reduce battery life.
Use only for initial setup and maintenance testing.
Notice!
In the normal operating mode, an alarm can be transmitted only
after three (3) minutes have passed since the previous alarm
restoral. This 3 minute lockout time reduces unnecessary RF
transmissions in high traffic areas, thereby extending battery
life.
Refer to the LED table below for LED descriptions.
LED condition
Steady blue
Flashing blue
Bosch Security Systems B.V.
433.42 MHz
Cause
PIR activation (Walk Test)
Warm-up period after power-up
RADION PIR C | en
2020.05 | 13 | F.01U.261.834
61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B810-chi

Table of Contents