Example of Setting
Panel setting is set as following.
SONY ROUTING SYSTEM SETUP MENU
SET PANEL TABLE(SOURCE)
CONTROL DESTINATION = OUT015
01 KEY=EX001
02 KEY=EX002
05 KEY=IN006
06 KEY=IN007
09 KEY=.......
10 KEY=.......
13 KEY=.......
14 KEY=.......
Fig. 5 N: SET PANEL TABLE
Local phantom setting is set as following.
SONY ROUTING SYSTEM SETUP MENU
SET PHANTOM TABLE (PHANTOM:DESTINATION<SOURCE-LEVEL) (G.PHANTOM NAME:NUMBER)
PHANTOM | DEST
| SOURCE | LEVEL1-8 | PHANTOM | DEST
EX001
: DST+000 < IN005
- 10000000 | EX001
EX002
: DST+000 < IN005
- 10000000 | EX002
EX003
: DST+000 < IN005
- 10000000 | EX003
EX004
: DST+000 < IN005
- 10000000 | EX004
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
0=IN
1=OUT
2=GPH
3=LPH
8=ggg
9=hhh
A=iii
B=jjj
G=....
H=....
I=qqq
J=rrrr
O=www
P=xxx
Q=yyy
R=zzz
Ctrl-E:MENU Ctrl-D:RETURN Ctrl-N:DESCRIP.NAME G:GLOBAL PHANTOM +:DST+
Fig. 6 Example of Local Phantom Setting
Route function is set as following. Enter the offset value by
entering "+" key at the DEST setting area.
SONY ROUTING SYSTEM SETUP MENU
SET ROUTE(ROUTE DESTINATION:DESTINATION<SOURCE-LEVEL)
ROUTE
| DEST
| SOURCE | LEVEL1-8 | ROUTE
OUT001 : DST+000 < IN005
- 10000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
Fig. 7 R: SET ROUTE
5-4
BKS-R1617A V2.23
STATION NUMBER 10
03 KEY=EX003
04 KEY=EX004
07 KEY=IN008
08 KEY=.......
11 KEY=.......
12 KEY=.......
15 KEY=.......
16 KEY=.......
BKS-R1617A V2.23
STATION NUMBER 5
| SOURCE | LEVEL1-8
: OUT001 < IN001
- 10000000
: OUT001 < IN002
- 10000000
: OUT001 < IN003
- 10000000
: OUT001 < IN004
- 10000000
4=ccc
5=ddd
6=eee
7=fff
C=kkk
D=lll
E=mmm
F=nnn
K=ssss
L=tttt
M=uuuu
N=vvv
S=AAA
T=BBB
U=CCC
V=DDD
BKS-R1617A V2.23
STATION NUMBER 10
PAGE = 1
| DEST
| SOURCE | LEVEL1-8
Example of Operation
Predefined cross-point can be switched by selecting EX001
to IN006 when the Control Destination is selected by
pressing OUT015 key. IN001 to IN008 will be displayed
as the status of cross-point for OUT015 at this time.
Key
Switching Cross
Selection Point
EX001 to
INxxx-OUT001/IN005-OUT015 One of IN001 to IN004
EX004
Phantom will be executed
IN006
INxxx-OUT015
to IN008
Ordinary switching
Fig. 8 Example of Operation
The same operation is performed when OUT016 is select-
ed. Since the status display of cross-point for route func-
tion traces and displays the cross-point, it will display
IN001 in the status when Take is performed on EX001 on
OUT015, but the route function is cancelled on OUT015
when the Control Destination is changed from OUT015 to
OUT016, and IN005 (trunk destination) is displayed on
OUT015.
Status Display
is displayed depending
on the route function
IN006 to IN008 is
displayed