A.2.26 Object 2216h: FIR5 Sample Data
Data for the Finite Impulse Response filter.
OBJECT DESCRIPTION
INDEX
Name
Object Code
Data Type
ENTRY DESCRIPTION
Access
PDO Mapping
Default Value
A.2.27 Object 2217h: Selected FIR Filter
OBJECT DESCRIPTION
INDEX
Name
Object Code
Data Type
ENTRY DESCRIPTION
Access
PDO Mapping
Default Value
A.2.28 Object 2218h: FIR Pre-scaler
OBJECT DESCRIPTION
INDEX
Name
Object Code
Data Type
ENTRY DESCRIPTION
Sub-Index
© 2018 Baker Hughes, a GE company – All rights reserved.
DOMAIN
RW
No
NULL
2216
FIR5 Sample Data
Variable
DOMAIN
RW
No
NULL
2217
Selected FIR filter
Variable
UNSIGNED8
RW
No
0x02
2218
FIR Prescaler
Array
UNSIGNED16
000