4.4.3.2
Line/load connection
Table 4-2
Type of connection
Terminals
Line supply connection (line supply)
Load connection (load)
Basic Line Filter for Active Line Modules
16 kW
36 kW
55 kW
1) for ring cable lugs to DIN 46234
4.4.4
Dimension Drawing
Figure 4-5
Dimension drawing: Basic Line Filter for Active Line Modules (16 kW to 55 kW)
Table 4-3
Dimensions: Basic Line Filter for Active Line Modules
Basic Line
Order number
Filter
16 kW
6SL3000-0BE21-6DAx
36 kW
6SL3000-0BE23-6DAx
55 kW
6SL3000-0BE25-5DAx
Booksize cold-plate power units
Manual, (GH4), 03.2007, 6SL3097-2AJ00-0BP4
4.4 Basic Line Filter for Active Line Modules with line reactor
Designations
L1, L2, L3, PE
L1´, L2´, L3´, PE
Screw terminal: 10 mm
3-pin/1.5 -1.8 Nm (see Screw Terminals chapter)
2
PE connection: M6/6 Nm
Screw terminal: 35 mm
2
PE connection: M6/6 Nm
Screw terminal: 50 mm
/6 - 8 Nm
2
PE connection: M6/6 Nm
W [mm]
w [mm]
(inches)
(inches)
429 (16.88)
50 (1.96)
433 (17.07)
75 (2.95)
466 (18.34)
100 (3.93)
1)
1)
1)
a [mm]
(inches)
15 (0.59)
15 (0.59)
15 (0.59)
Line connection
H [mm]
h [mm]
(inches)
(inches)
156 (6.14)
31 (1.22)
135 (5.31)
68 (2.67)
148 (5.82)
54 (2.12)
43