Siemens SINAMICS S120 Equipment Manual page 197

Booksize cold-plate power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 8-12
Technical data of Double Motor Modules with cold plate cooling (2 x 3 to 2 x18 A)
Voltage
Infeed:
DC link voltage
Electronics power supply
Output voltage
Overvoltage tripping
Undervoltage tripping
Electronics current consumption at 24 V
DC link busbar current carrying capacity
24 V busbar current carrying capacity
Rated output current
Base load current I
base
Intermittent duty current l
Peak current
Rated power
(with DC link voltage of 600 V
frequency of 4 kHz)
Max. pulse frequency without derating
Max. pulse frequency with derating
Max. permissible heat sink temperature
Max. ambient temperature without derating
Max. ambient temperature with derating
DC link capacitance
Weight
Rated duty cycles of Motor Modules booksize
Figure 8-9
Booksize cold-plate power units
Manual, (GH4), 03.2007, 6SL3097-2AJ00-0BP4
6SL3126-2TE
V
V
V
V
V
A
A
A
A
A
40%
A
S6
A
kW
and clock
DC
kHz
kHz
°C
°C
°C
μF
kg
Peak current duty cycle with prior loading
13-0AA0
DC
DC
ACrms
DC
DC
DC
100
DC
20
DC
2x3
ACrms(In)
2x2.6
2x3.5
ACrms(Is6)
2x6
ACrms(Imax)
1,6
75
110
4,5
Motor Modules with Cold Plate
8.6 Technical Specifications
15-0AA0
21-0AA0
510 –720
24 (20,4 – 28,8)
0 - 480
820 ± 2%
380
See Chapter Cabinet design, Booksize.
100
100
20
20
2x5
2x9
2x4.3
2x7.7
2x6
2x10
2x10
2x18
2,7
4,8
4
16
75
85
40
55
220
220
4,5
4,5
21-8AA0
100
20
2x18
2x15.3
2x24
2x36
9,7
80
705
5,9
197

Advertisement

Table of Contents
loading