Overview And How To Use Test Print (Pg) In Service Mode - Canon imagePRESS C800 Series Troubleshooting Manual

Hide thumbs Also See for imagePRESS C800 Series:
Table of Contents

Advertisement

Chapter 1
Service Mode > COPIER > Display > FIXING > FX-MTR5
Service Mode > COPIER > Display > FIXING > FX-R-TM
Service Mode > COPIER > Counter > FIXING > FX-RF-RL
Service Mode > COPIER > Counter > CLEANING > FX1-RFRL
Service Mode > COPIER > Counter > PRDC-1 > FXLW-TH1
Service Mode > COPIER > Counter > PRDC-1 > FXLW-TH2

1.1.7.1.51 Overview and how to use test print (PG) in service mode

[ Manual-related ]
Description
This machine is able to use following test prints. With each test print, the image error can be checked by "Yes" in the following image check items.
If the image failure occurred on normal output does not reappear on the test print, it may be caused by the PDL input or reader side.
Field Remedy
a) Test print type
PG
TYPE Pattern
TYPE
0
Normal copy/print
1 to 3 (For R&D)
4
16-Gradation
5
Full Area Half Tone
6
Grid
10
MCYBk Horizontal Line
12
64-Gradation
14
Full Color 16-gradation
b) Selecting Test Print TYPE
b-1) Set the copy count, paper size, and pickup mode (single-sided or double-sided).
b-2) Select service mode > COPIER > Test > PG > TYPE.
b-3) Enter the appropriate TYPE No. using the keypad, and press the OK key.
b-4) Set the density using service mode > COPIER > Test > PG > DENS-Y/M/C/K (valid only if TYPE > 5).
b-5) Set the image mode by service mode > COPIER > Test > PG > TXPH.
b-6) Press the start key.
c) How to check test print
c-1) 16-Gradation (TYPE > 4)
1-136
Transfer
Gradation
Fogging
Fault
Yes
Yes
Yes
Yes
Yes
Yes
Display Fixing Motor current VL log: standby
Display Fixing Refresh Roller total operation times
Fixing Refresh Roller parts counter
Fixing Refresh Roller cleaning counter
Pressure Sub Thermistor 1 parts counter
Pressure Sub Thermistor 2 parts counter
Items
Uneven
Black line
White line
Density
Yes
Yes
Yes
Yes
Yes
Uneven
Color
Density
displaceme
Right Angle
at the
nt
Front/Rear
Yes
Yes
Yes
Yes
0031-6206
Originator
Straight
Lines
---
---
Main
Yes
controller
PCB

Hide quick links: