Sony BDX-E1000 Installation Manual page 19

Mpeg encoder unit, audio input board, 4:2:2 profile upgrade board, scrambler board
Hide thumbs Also See for BDX-E1000:
Table of Contents

Advertisement

S201-2 to S201-6 (A-3) : Factory use only
Factory setting : All switch levers are set to CLOSE
(lower position).
n
Be sure to use S201-2 to S201-6 with factory setting.
OPEN
1
2
3
4
5
6
7
S201-7 (A-3) : RS-232C/ISR select switch
Selects the mode of the RS-232C control port.
OPEN
: ISR mode
CLOSE
: Normal operation
Factory setting : CLOSE (lower position)
n
After this setting is changed, turn the power off and on
again or push the reset switch (S101).
S201-8 (A-3) : 525/625 select switch
Selects the video input mode.
CLOSE
: 625/50 Hz (PAL) system
OPEN
: 525/60 Hz (NTSC) system
Factory setting : CLOSE (lower position)
n
After this setting is changed, turn the power off and on
again or push the reset switch (S101).
S202 (A-5) :
0 : Resume mode
4 : Host control mode
Factory setting : 4
[Indicator]
D104 (A-4) (red) : BOOT ERROR indicator
Lights up when CPU does not boot up.
D105 (A-4) (orange) : BATTERY ALARM indicator
Lights up when the lithium battery (B101) for data backup
runs down.
D106 (A-4) (green) : POWER indicator
Lights up during the power supply operates normally.
BDX-E1000
indicates
8
the switch lever position.
D107 (A-4) (red) : SYSTEM ERROR indicator
Lights up when the system error occurs.
When the indicator D107 lights up, the indicator on the
front panel blinks in red.
At this time, check on the error state with the display of the
indicator D209.
D110 (A-5) (green) : LAN RECEIVED indicator
Lights up when data is received in the ethernet port.
D111 (A-5) (green) : LAN TRANSMITTED indicator
Lights up when data is transmitted to the ethernet port.
D201 to D208 (A-2) (orange) : Factory use only
D209 (A-6) :
STATUS indicator (7-segment LED)
During the normal operation, displays the bit rates of the
video signal. (Unit: Mbps)
When the indicator D107 lights up, displays a numerical
indication of the error state.
Number
Error state
00
Fan motor failure
10 to 1F
SY-240 board failure
20 to 2F
APR-25 board or DPR-93 board failure
30 to 3F
ENC-40 board failure
40 to 4F
VPR-33 board failure
50 to 5F
Bit stream output error
60 to 6F
Hardware error other than described above
70 to 7F
Software error other than described above
81 to 82
*1
Video input mode error
*1: When the number 81 to 82 is displayed, check the
following items.
. The mode of input signal matches with the mode
setting of 525/625.
. In the case of SDI input mode, the mode of input
signal matches with the mode setting of Digital
Component/Digital Composite.
n
When S202 on the SY-240 board is set to "4" (Host
control mode) , this unit becomes Digital
Component mode at power-on.
If a digital composite signal is input in Digital
Component mode, a system error will result.
1-7. Internal Switches and Indicators
1-11 (E)