Internal Switches And Indicators; Apr-25 Board - Sony BDX-E1000 Installation Manual

Mpeg encoder unit, audio input board, 4:2:2 profile upgrade board, scrambler board
Hide thumbs Also See for BDX-E1000:
Table of Contents

Advertisement

1-7. Internal Switches and Indicators

1-7. Internal Switches and Indicators

1-7-1. APR-25 Board

J
H
G
F
E
D
S904
C
B
D909
D916
A
1
2
3
4
5
6
n
The addresses on the board are shown by ( ) marks.
[Switch]
S101, S201, S301, S401 :
INPUT REFERENCE LEVEL select switches
Select the reference level of the analog audio input CH1 to
CH4 respectively.
Reference level
Channel Switch
+ + + + + 4 dBm0 dBm _ _ _ _ _ 3 dBm
CH1
S101(J-12) +4
CH2
S201(J-11) +4
CH3
S301(J-9)
+4
CH4
S401(J-8)
+4
n
When the factory setting is changed, perform the adjust-
ment in accordance with "2-3. APR-25 Board Adjustment"
in the Maintence Manual.
S102, S202, S302, S402:
INPUT HEADROOM select switches
Select the headroom of the analog audio input CH1 to CH4
respectively.
Headroom
Channel Switch
20 dB 18 dB 16 dB
CH1
S102(H-13) 20
CH2
S202(H-11) 20
CH3
S302(H-10) 20
CH4
S402(H-9)
20
1-8 (E)
S401
S301
S201
S101
S402
S302
S202
S102
S905
S501
S532
S502
S903
S531
S632
S631
D917
D924
S906
7
8
9
10
11
12
13
A side (Component side)
Factory setting
0
_3
+4
0
_3
+4
0
_3
+4
0
_3
+4
Factory setting
18
16
20
18
16
20
18
16
20
18
16
20
n
When the factory setting is changed, perform the adjust-
ment in accordance with "2-3. APR-25 Board Adjustment"
in the Maintence Manual.
S532, S632 : OUTPUT REFERENCE LEVEL select switches
Select the reference level of the monitor output LCH/RCH
respectively.
Reference level
Channel Switch
+ + + + + 4 dBm 0 dBm _ _ _ _ _ 3 dBm _ _ _ _ _ 20 dBm
S532(E-10) +4
LCH
0
RCH
S632(D-10) +4
0
n
When the factory setting is changed, perform the adjust-
ment in accordance with "2-3. APR-25 Board Adjustment"
in the Maintence Manual.
S531, S631 : OUTPUT HEADROOM select switches
Select the headroom of the monitor output LCH/RCH
respectively.
Headroom
Channel Switch
20 dB 18 dB 16 dB
LCH
S531(D-10) 20
RCH
S631(B-10) 20
n
When the factory setting is changed, perform the adjust-
ment in accordance with "2-3. APR-25 Board Adjustment"
in the Maintence Manual.
S501 (E-8), S502 (E-8), S903 (E-7), S904 (C-5) :
Factory use only
Factory setting :
S501
S502
DEC
DECLR/DECBCK
n Be sure to use these switches with factory setting.
S902 (M-7) :
Serial number 10001 to 10030
Serial number 10031 and higher : Not mounted
S905 (G-10) : Factory use only
Factory setting : ON
n Be sure to use this switch with factory setting.
Factory setting
_3
_20
+4
_3
_20
+4
Factory setting
18
16
20
18
16
20
S903
S904
DEC
DEC
: Unassigned