Infeed At Both Reversal Points - Siemens SINUMERIK 840D sl Function Manual

Extended functions
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Programming
Reversal point range 2:
WHENEVER $AA_IM[Z] < $SA_OSCILL_REVERSE_POS2[Z] - ii2
DO $AA_OVR[X] = 0
Explanation:
$AA_IM[Z]: Current position of oscillating axis Z
$SA_OSCILL_REVERSE_POS2[Z]: Position of reversal point 2 of the oscillation axis
$AA_OVR[X]: Axial override of the infeed axis
ii2: Magnitude of reversal range 2 (user variable)
Infeed
The absolute infeed value is defined by instruction POSP.
See Chapter "Defining Infeed POSP".
Assignment
The assignment between the oscillation axis and the infeed axis is defined by instruction
OSCILL.
See Chapter "Assignment of Oscillating and Infeed Axes OSCILL".
12.3.3

Infeed at both reversal points

General procedure
The functions described above for infeed at the reversal point and in the reversal point range
can be freely combined.
Combinations
Infeed:
to U1 - to U2
to U1 - range U2
range U1 - to U2
range U1 - range U2
Extended Functions
Function Manual, 01/2008, 6FC5397-1BP10-3BA0
12.3 Oscillation controlled by synchronized actions
Oscillation (P5)
817