Table 3.7 Front Panel Components Of The Tepria - Samsung OfficeServ 7400 Technical Manual

Hide thumbs Also See for OfficeServ 7400:
Table of Contents

Advertisement

OfficeServ 7400
TECHNICAL MANUAL
FRONT VIEW OF TEPRIa BOARD
The front view of the TEPRIa board is shown in the picture below.
UNUSED
Port, LED
P1
Port for connecting T1/E1/PRI cables
LAN
Port for connecting to Ethernet (reserved for future use)
SIO
Serial port for internal Samsung engineering use only.
TP1 LED
Indicates the type of the circuit connected to port P1
- On: PRI in operation
- Off: T1/E1 in operation
L21 LED
This LED indicates the operation status of Layer 2
- On: The PRI Layer2 is operating properly. PRI message is being received.
- Off: The PRI Layer2 is operating abnormally.
AIS1 LED
This LED indicates whether the T1/E1 remote alarm has been generated.
- On: The remote alarm has been generated. All one's are being received (Error)
- Off: The remote alarm has not been generated (Normal).
LOS1 LED
This LED indicates loss of signal.
- On: Signals have been lost, no PCM clocking is being received.
- Off: Signals being received (Normal).
SYN1 LED
Clock synchronization.
- On: Indicates loss of framing (Error Condition).
- Off: Clocks are synchronized when they inter-work with the counterpart station
(Normal).
RUN LED
LED turns ON green: When T1 operates in normal(Blink in the cycle of 200 ms)
LED turns ON orange: When E1 operates in normal(Blink in the cycle of 200 ms)
CLK LED
This LED indicates whether this board is a master or slave.
- On: The board has received the synchronization clock from the counterpart
station.
- Off: Using synchronous clock for internal clock.
RST button
Card Reset button
Figure 3.19 Front View of the TEPRIa

Table 3.7 Front Panel Components of the TEPRIa

Function Description
3.22
Table of Contents