Table 5.1 Consumption Per Device - Samsung OfficeServ 7400 Technical Manual

Hide thumbs Also See for OfficeServ 7400:
Table of Contents

Advertisement

OfficeServ 7400
TECHNICAL MANUAL
CARD Name
16DLI2
2-Line LCD Keyset
Analog Phone
16SLI2
16MWSLI
MW Phone
PLIM or GPLIM
ITP-5021D, ITP-5107S, ITP-5121D
(current drawn
ITP-5112L
from connected
SMT-R2000 Dual AP
devices)
GWIM
DATA
(current drawn
GSIM
from modules)
GPLIM
IF ADDING GPLIM/PLIM CONNECTED DEVICES, GWIM or GSIM modules CAUSE
CURRENT DRAWN TO EXCEED 6600mA PER CABINET (not per system), THEN
YOU MUST CONNECT THE OS7150 EXTERNAL PoE POWER SUPPLY MODULE to
the cabinet.
It is important to note that the OS 7150 can only provide additional power to the PLIM,
GPLIM, GWIM and GSIM. The OS 7150 is used when the GSIM, GWIM or PoE devices
connected to GPLIM/PLIM causes the total current draw per cabinet to exceed
6600mA. It does not provide power to DLI ports, MWSLI ports and other system
interface cards.
The internal jumpers must be set correctly for the four modules mentioned above to
use the external OS7150 PoE power supply.
PRODUCT SAFETY
Electric Shock
Make sure to turn this product OFF when handling it. Handling this product with AC
power ON may cause electric shock.
Device
Type

Table 5.1 Consumption per Device

5.3
Home Page
INSTALLATION
PART 5 JUNE 2006
Current Comsumption
for Each Device (mA)
25
25
30
100
130
200
450
320
35
Table of Contents