8.1.4.3
Installing the Braking Module in a Smart Line Module / Active Line Module / Motor
Module, frame size HX
Figure 8-10
Installing the Braking Module
The steps for the installation procedure are numbered in accordance with the diagram.
1. Insert the Braking Module.
2. Tighten the 4 retaining screws for the Braking Module.
3. Secure the connection clip to the DC link (DCPA/DCNA) with two screws (Braking Module
connection) and two nuts (DC-link connection).
Note
Pay attention to the tightening torques
The tightening torques specified in the table "Tightening torques for screw connections" must
be observed.