Siemens SINAMICS S120 Equipment Manual page 317

Air-cooled chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 7- 13
Technical data, Motor Modules Chassis-2, 510 ... 720 V DC (line voltage 3 AC 380 ... 480 V), Part 2
Article number
Output current
- Rated current I
N A
- Base load current I
L
- Base load current I
1)
H
- Max. output current I
max
Type rating
- Based on I
(50 Hz 400 V)
L
- Based on I
(50 Hz 400 V)
H
- Based on I
(60 Hz 460 V)
L
- Based on I
(60 Hz 460 V)
H
DC link current
Rated current I
N DC
Supply voltages
- DC-link voltage
- Electronic power supply
- Output voltage
Rated pulse frequency
- Max. pulse frequency without derating
- Max. pulse frequency with derating
Max. ambient temperature
- Without derating
- With derating
DC-link capacitance
Current consumption
- Electronics current consumption (24 V DC)
- Fan supply, at 3 AC 400 V, 50/60 Hz
Power loss, max.
4)
- at 50 Hz 400 V
- at 60 Hz 460 V
Cooling air requirement
Sound pressure level
L
(1 m) at 50/60 Hz
pA
Connections
- DC link connection
- Motor connection
- PE connection
Max. conductor cross-sections
- DC link connection (DCP, DCN)
- Motor connection (U2, V2, W2)
- PE connection
Motor cable length, max.
- shielded
- unshielded
Degree of protection
Dimensions
- Width
- Height
- Depth
Air-cooled chassis power units
Manual, 07/2019, 6SL3097-4AE00-0BP9
6SL3321–
A
A
A
A
kW
2)
kW
2)
HP
3)
HP
3)
A
V
DC
V
DC
V
ACrms
kHz
kHz
kHz
° C
° C
μF
A
A
kW
kW
m
/s
3
dB(A)
mm²
mm²
5)
m
m
mm
mm
mm
1TE41–2AA0
1200
1145
1000
1680
630
560
950
850
1440
24 (20.4 ... 28.8)
0 ... 0.75 x DC link voltage
2.5
2.5
8
45
60
25900
1.3
1.8 / 1.8
10.4
10.8
0.64
72.5
4 x M12
6 x M12
6 x M12
Busbar
6 x 240
6 x 240
300
450
IP00
280
1491
542
Motor Modules Chassis-2
7.8 Technical data
510 ... 720
315

Advertisement

Table of Contents
loading

Table of Contents