Serial Port Connectivity - Siemens SIMATIC HawkEye 1600T Series Manual

Smart camera
Table of Contents

Advertisement

Chapter
2
System Components
TABLE 2–2.
Port Name
Protocol
Reports &
TCP
Statistics Control
Port
Serial TCP Ports
TCP
Camera
UDP
Login/Command
Port
Camera Announce
UDP
Port

Serial Port Connectivity

FrontRunner always communicates over Ethernet with the SIMATIC
HawkEye™ 1600T Smart Camera; however, the Serial port is fully supported by
the Job in the form of allowing Serial triggers and Serial ASCII reporting output
via the Acquire, Digital Input and Formatted Output Tools.
The serial string(s) are formatted using the *printf C syntax*. Special characters
can be used and are summarized in Table 2–3.
TABLE 2–3.
Sequence
\a
\b
\f
\n
\r
\t
\v
\'
2-4
SIMATIC HawkEye™ 1600T TCP/IP Connectivity (Continued)
Number
Note
49202
Allow control over a Report Connection, in particular
update rate and allows records to be added/removed
from the connection.
49211
Send Formatted Output Strings serially over TCP as
49212
programmed in the avp by the Formatted Output Step
49213
49214
49493
Gains control to the camera in order to edit and modify
its network parameters. A network login to the camera
is required to gain control with the HE1600.
49495
Broadcasts HE1600T Smart Camera identity on the
current subnet used by Network View in FrontRunner,
provides general counters, camera name, IP, IP in
control, camera status, and camera software version.
Special Characters
Output Character
Bell (alert)
Backspace
Formfeed
New line
Carriage return
Horizontal tab
Vertical tab
Single quotation mark
SIMATIC HawkEye™ 1600T Smart Camera Guide