REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
PPTC MODIFIED WIRING FOR EXTERNAL MODEM TO TTY CONNECTION
PPCT (Modular to DB25) ADAPTOR, MODIFIED WIRING FOR
CONNECTING TTY JACK TO AN EXTERNAL MODEM:
QSMU OR PIOU/PIOUS,
TTY JACK
MODULAR PIN NO.
1
2
3
4
5
6
IMPORTANT:
REMOTE
MODEM
RS-232
CABLE
FIGURE 4
REMOTE MAINTENANCE USING IMDU MODEM (DK16 ONLY)
TABLE RM-A
PPTC1A-5M ADAPTOR
MODULAR PIN NO.
to
RD
RD,
6
to
to
TD
TD,
5
to
to
DSR
DSR,
4
to
to
DTR
DTR,
3
to
to
DCD
DCD,
2
to
to
SG
SG,
1
to
*
PPTC1A-5M, pins 2 & 3 and pins 8 & 20 must
be reversed in the field, as shown, for modem
connection. Set Hayes modem to track status of
carrier detect signal (AT & C1) and to answer
(ATS0 = 1).
CO LINE
TELEPHONE
NETWORK
-4-
MODEM
RS-232
LEAD NAME
DB25 PIN NO.
3*
RD
2*
TD
6
DSR
20*
DTR
8*
DCD
7
SG
4 Jumper to 5
RTS to CTS
PIOU OR PIOUS
IMDU
DK16
CO LINE
CO LINE
CIRCUIT
DK16
CO line connects to IMDU port (619)
via: DISA, Ring transfer, or ringing
assignments in Program 78
ROM
AND
RAM
TIME
SWITCH