Dc Link Supply Adapter; Description; Safety Information - Siemens SINAMICS S120 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

7.2

DC link supply adapter

7.2
7.2.1

Description

The DC link supply adapter supplies the DC link voltage directly. With a direct supply, each
component is connected to the DC link separately. The internal DC link busbar is not used
here.
The connection cables must be fused accordingly.
Note
When a DC link infeed adapter and DC busbars are used, the limit values for radio inter-
ference emission acc. to Class A1 acc. to EN 55011 or Category C2 acc. to EN 61800-3 can
no longer be complied with.
It is not possible to use the DC link supply adapter in conjunction with internal DC link
busbars.
Table 7-6
The DC link supply adapter is available in two sizes.
for Line/Motor Modules with a width of
50 mm and 100 mm
Screw terminals (4 to 10 mm²)
7.2.2

Safety Information

Danger
Risk of electric shock. A hazardous voltage is present for up to 5 minutes after the power
supply has been disconnected.
This time must elapse before any work may be carried-out on the adapter (e.g. mounting/
installation).
When opening the protective cover for the DC link, you must activate the release. A suitable
tool (e.g. screwdriver) must be used for this purpose.
The components must only be operated when the protective cover of the DC link is closed.
Damaged components must not be used, otherwise this could result in secondary damage
or accidents.
Equipment Manual for Booksize Power Units
Equipment Manual, (GH2), 03/2006 Edition, 6SL3097-2AC00-0BP3
for Line/Motor Modules with a width of
150 mm, 200 mm, 300 mm
Screw terminals (35 to 95 mm²)
Options
7.2 DC link supply adapter