Siemens SITRANS T Series Operating Instructions Manual

Multipoint temperature transmitter
Hide thumbs Also See for SITRANS T Series:

Advertisement

Quick Links

SITRANS T
Multipoint Temperature Transmitter
SITRANS TO500
Operating Instructions
04/2017
A5E39322264-AC
___________________
Introduction
___________________
Safety information
___________________
Description
___________________
Mounting and connecting
___________________
Operating
___________________
Commissioning
___________________
Service and maintenance
___________________
Technical specifications
___________________
Dimensional drawings
___________________
Appendix
1
2
3
4
5
6
7
8
9
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SITRANS T Series

  • Page 1 ___________________ Introduction ___________________ Safety information ___________________ SITRANS T Description ___________________ Mounting and connecting Multipoint Temperature Transmitter SITRANS TO500 ___________________ Operating ___________________ Commissioning Operating Instructions ___________________ Service and maintenance ___________________ Technical specifications ___________________ Dimensional drawings ___________________ Appendix 04/2017 A5E39322264-AC...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ............................. 5 Purpose of this documentation ....................5 History ............................5 Industrial use note ........................5 Checking the consignment ....................... 6 Security information ........................6 Notes on warranty ........................7 Transportation and storage ....................... 7 Safety information ........................... 9 Prerequisites for safe use ......................
  • Page 4 Table of contents Setting the PROFIBUS address ..................... 27 Password ..........................27 Changing the IP address ....................... 28 Resetting the IP address and PROFIBUS address ............... 28 Service and maintenance ........................29 Basic safety information ......................29 Restarting the device ......................29 Cleaning the enclosure ......................
  • Page 5: Introduction

    Introduction Purpose of this documentation These instructions contain all information required to commission and use the device. Read the instructions carefully prior to installation and commissioning. In order to use the device correctly, first review its principle of operation. The instructions are aimed at persons mechanically installing the device, connecting it electronically, configuring the parameters and commissioning it, as well as service and maintenance engineers.
  • Page 6: Checking The Consignment

    In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 7: Notes On Warranty

    The sales contract contains all obligations on the part of Siemens as well as the complete and solely applicable warranty conditions. Any statements regarding device versions described in the manual do not create new warranties or modify the existing warranty.
  • Page 8 Introduction 1.7 Transportation and storage SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 9: Safety Information

    Safety information Prerequisites for safe use This device left the factory in good working condition. In order to maintain this status and to ensure safe operation of the device, observe these instructions and all the specifications relevant to safety. Observe the information and symbols on the device. Do not remove any information or symbols from the device.
  • Page 10: Conformity With European Directives

    Due to the large number of possible applications, each detail of the described device versions for each possible scenario during commissioning, operation, maintenance or operation in systems cannot be considered in the instructions. If you need additional information not covered by these instructions, contact your local Siemens office or company representative. Note...
  • Page 11: Description

    Description System configuration Figure 3-1 System configuration SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 12: Area Of Application

    Description 3.2 Area of application Area of application The multipoint temperature transmitter SITRANS TO500 (device) is used for evaluating a large number of sensors (Fiber Bragg grating, short form: FBG) arranged on a fiber-optic multipoint temperature measurement lance. Up to 4 measurement lances with up to 48 sensors each can be processed simultaneously by a SITRANS TO500.
  • Page 13: Design

    Description 3.4 Design Design ① ⑥ Channels for connection of the measurement lances "Reset" button ② ⑦ PROFIBUS DP connector "Power" and "Status" LEDs V0/V1 RS485 ③ ⑧ Ethernet connector Nameplates RJ45 for LAN (TCP/IP) ④ ⑨ Measurement lance Ventilation slots ⑤...
  • Page 14: Nameplate Layout

    Description 3.5 Nameplate layout Nameplate layout ① IP address ② Subnet mask ③ Serial number ④ Order number Figure 3-3 Example of the layout of the nameplates SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 15: Mounting And Connecting

    Mounting and connecting Introduction Figure 4-1 Note during mounting and connecting SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 16: Mounting The Device

    Technical specifications (Page 33) Note Material compatibility Siemens can provide you with support concerning selection of sensor components wetted by process media. However, you are responsible for the selection of components. Siemens accepts no liability for faults or failures resulting from incompatible materials.
  • Page 17: Connecting The Device

    Mounting and connecting 4.3 Connecting the device Connecting the device Procedure 1. You can optionally connect the device to your PC with an RJ45 cable for commissioning. 2. Connect the device to PROFIBUS using V0/V1 RS485. 3. Read the description included with the measurement lance to determine which measurement lance has to be connected to which channel on the device.
  • Page 18 Mounting and connecting 4.3 Connecting the device SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 19: Operating

    Operating Parameter assignment software You can operate and configure the device with the included parameter assignment software. See section Connecting the device (Page 17). Viewing the temperature characteristic (Temperature) The temperature characteristic curves of the channels (Channel) are displayed in the "Temperature"...
  • Page 20 Operating 5.3 Viewing the spectrum of the channel (Spectral View) A temperature range is assigned to each sensor. The blue vertical line indicates the defined minimum temperature. The red vertical line indicates the defined maximum temperature. Each FBG peak that lies within the defined temperature range and the threshold value is marked in the diagram, e.g.
  • Page 21: Viewing Calibration Data (Measurement Config)

    Operating 5.4 Viewing calibration data (Measurement Config) If an FBG peak is outside the defined temperature range, the FGB peak is not labeled. Figure 5-4 Parameter assignment software: Spectral View tab: An FBG peak is not in the defined temperature range Viewing calibration data (Measurement Config) Each channel is displayed with its sensors and all data in the "Measurement Config"...
  • Page 22 Operating 5.4 Viewing calibration data (Measurement Config) Sensor Index See section Sensor positions (Page 40). Polynomial Index Sensor Index 1 uses the polynomial 70 Calibration Wavelength Basic wavelength Minimum temperature in the temperature range of the sensor Maximum temperature in the temperature range of the sensor Figure 5-5 Parameter assignment software: Measurement Config tab: Calibration data of the measurement lance at channel 1...
  • Page 23: Commissioning

    Commissioning PC setup Requirement The device is connected. See section Connecting the device (Page 17). Procedure 1. Navigate in Windows to the "Local Area Connection" dialog. 2. Right-click on "Local Area Connection" and select "Properties" in the shortcut menu. Figure 6-1 Windows Control Panel Network Connections SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 24 Commissioning 6.1 PC setup 3. Select "Internet Protocol Version 4 (TCP/IPv4)" and click the "Properties" button. Figure 6-2 Windows: "Local Area Connection" window 4. Enter an IP address that is available in your network. For example, 10.0.0.2. Do not enter the IP address of the device;...
  • Page 25 Commissioning 6.1 PC setup 5. Enter the subnet mask of the device. You can find the subnet mask of the TO500 on the nameplate (Page 17). Figure 6-3 Windows: "Internet Protocol Version 4 TCP/IPv4 Properties" window 6. Click "OK". See also Nameplate layout (Page 14) SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 26: Installing The Parameter Assignment Software

    1. Open the FTP server of the device: ftp://10.0.0.10/. 2. Copy the "Sitrans_TO_WebServerLauncher" folder locally on your PC. 3. Open the startup.exe file. 4. Start the parameter assignment software using the Windows Start menu: Siemens > Sitrans TO > Sitrans TO_WS_Launcher. Result The "Temperature characteristic"...
  • Page 27: Setting The Profibus Address

    Commissioning 6.4 Setting the PROFIBUS address Setting the PROFIBUS address Procedure 1. Open the "System Config" tab. 2. In the "NewAddress" field, enter the number 5, for example. 3. Click the "Set Address" button. Figure 6-4 Parameter assignment software: System Config tab Result The "CurrentAddress"...
  • Page 28: Changing The Ip Address

    Commissioning 6.6 Changing the IP address Changing the IP address Procedure 1. Open the "System Config" tab. 2. Enter the required new IP address in the field "IP Address". 3. Click the "Set Address" button. Figure 6-5 Parameter assignment software: Tab: System Config Resetting the IP address and PROFIBUS address Requirement ●...
  • Page 29: Service And Maintenance

    WARNING Impermissible repair of explosion protected devices Risk of explosion in areas subject to explosion hazard. • Repair must be carried out by Siemens authorized personnel only. Restarting the device Requirement ● "Power" and "Status" LEDs light up. See section Design (Page 13).
  • Page 30: Cleaning The Enclosure

    Enclose the bill of lading, return document and decontamination certificate in a clear plastic pouch and attach it firmly to the outside of the packaging. Required forms ● Delivery note ● Return document (http://www.siemens.com/processinstrumentation/returngoodsnote) with the following information: – Product (item description) – Number of returned devices/replacement parts –...
  • Page 31: Disposal

    Devices can be returned to the supplier within the EC, or to a locally ap- proved disposal service for eco-friendly recycling. Observe the specific regulations valid in your country. Further information about devices containing batteries can be found at: Information on battery/product return (WEEE) (https://support.industry.siemens.com/cs/document/109479891/) SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 32 Service and maintenance 7.6 Disposal SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 33: Technical Specifications

    Technical specifications SITRANS TO500 Input Channels Measured variable Temperature Input type Max. 48 sensors (FBGs) per channel Characteristic curves Linear to temperature Resolution 0.1 K Measuring accuracy < 0.5 K Repeatability < 0.5 K Measuring cycle < 1 s Measuring range -180 ...
  • Page 34 4 slots • Each slot represents a channel. 240 bytes with 48 measured values in each slot. The acyclic services are only tested and available in Siemens automation systems. In H-systems Cyclic data exchange only SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 35: Measurement Lance (Typical)

    Technical specifications 8.2 Measurement lance (typical) Measurement lance (typical) Input Measured variable Temperature Measuring range Stainless steel coating -40 ... +450 °C (-40 ... 842 °F) 316 L, mat. no. 1.4409 Polymer coating -60 ... +200 °C (-76 ... 392 °F) Min.
  • Page 36: Certificates And Approvals

    Technical specifications 8.3 Certificates and approvals Certificates and approvals Certificates and approvals "Optical intrinsic safety" type of protection ATEX/IECEx II (1) G [Ex op is IIC T6 Ga] EN 60079-0/A11: 2013 II (1) D [Ex op is IIIC Da] IEC 60079-0: 2011 + Cor.: 2012 + Cor.: 2013 I (M1) [Ex op is I Ma] IEC/EN 60079-28: 2015 SITRANS TO500...
  • Page 37: Dimensional Drawings

    Dimensional drawings SITRANS TO500 Figure 9-1 TO500 front view, dimensions in mm (inch) Figure 9-2 TO500 rear view, dimensions in mm (inch) SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 38: Measurement Lances

    Dimensional drawings 9.2 Measurement lances Figure 9-3 TO500 side view, dimensions in mm (inch) Measurement lances ① Pigtail with FC/APC plug ② Handpiece ③ Glass fiber Cable length Installation length Figure 9-4 Measurement lance with FC/APC plug, pigtail and handpiece, dimensions in mm (inch) SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 39 Dimensional drawings 9.2 Measurement lances ① Pigtail with IP67 plug ② Handpiece ③ Glass fiber Cable length Installation length Figure 9-5 Measurement lance with IP67 plug, pigtail and handpiece, dimensions in mm (inch) ① IP67 plug ② Glass fiber Installation length Figure 9-6 Measurement lance with IP67 plug, without pigtail or handpiece ①...
  • Page 40: Sensor Positions

    Dimensional drawings 9.3 Sensor positions Sensor positions ① The sensor positions are measured from the end of the handpiece and numbered in the calibration data starting at the handpiece. Figure 9-8 Example of sensor positions, dimensions in mm (inch) Connecting cable from the measurement lance to the device ①...
  • Page 41: Appendix

    In addition to our documentation, Siemens provides a comprehensive support solution at: ● Service&Support (http://www.siemens.com/automation/service&support) Personal contact If you have additional questions about the device, please contact your Siemens personal contact at: ● Partner (http://www.automation.siemens.com/partner) In order to find the contact for your product, select under 'All Products and Branches' the path 'Automation Technology >...
  • Page 42 Appendix A.2 Certificates SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 43: Glossary

    Glossary Calibration The measurement channels are calibrated based on customer requirements. Channel Each measurement lance is connected to a channel of the multipoint temperature transmitter SITRANS TO500. Connecting cable Cable from the measurement lance to the device. Degree of protection The degree of protection of a device indicates the extent of protection.
  • Page 44 See FBG peak. Pigtail Glass fiber cable and plug Process Device Manager PDM is a Siemens software package for configuration, parameter assignment, commissioning and maintenance of network configurations and field devices. Part of SIMATIC STEP 7. Used for configuration and diagnostics. Sensor A sensor is a measuring point.
  • Page 45: Index

    Index Certificates, 9 Correct usage, (See improper device modifications) Customer Support Hotline, 41 Hazardous area Laws and directives, 9 Hotline, 41 Improper device modifications, 10 Internet, 41 Scope of delivery, 6 Service, 41 Support, 41 Symbols, (See warning symbols) Test certificates, 9 Warning symbols, 9 SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...
  • Page 46 Index SITRANS TO500 Operating Instructions, 04/2017, A5E39322264-AC...

This manual is also suitable for:

Sitrans to500

Table of Contents