• Output registers (YW)
Output register (YW)/output device (Y) assignments are shown below.
In the R/W column, the letter R means readable only and the term R/W, readable and
writable.
Register
YW 0000
YW 0003
YW 0004
YW 0005
YW 0006
YW 0013
YW 0014
YW 0015
YW 0016
YW 0031
YW 0032
YW 0047
YW 0048
YW 0063
YW 0064
YW 0079
YW 0080
YW 0095
YW 0096
YW 0111
YW 0112
YW 0127
YW 0128
YW 0143
YW 0144
YW 0159
YW 0160
YW 0175
YW 0176
YW 0191
YW 0192
YW 0207
YW 0208
YW 0223
YW 0224
YW 0239
YW 0240
YW 0255
6F8C1005
Direct
representation
%MW9.
512 Address 0: I/O module send buffer
%MW9.
515
%MW9.
516
%MW9.
517
%MW9.
518
%MW9.
525
%MW9.
526
%MW9.
527
%MW9.
528 Address 1: I/O MODULE SEND BUFFER
%MW9.
543
%MW9.
544 Address 2: I/O MODULE SEND BUFFER
%MW9.
559
%MW9.
560 Address 3: I/O MODULE SEND BUFFER
%MW9.
575
%MW9.
576 Address 4: I/O MODULE SEND BUFFER
%MW9.
591
%MW9.
592 Address 5: I/O MODULE SEND BUFFER
%MW9.
607
%MW9.
608 Address 6: I/O MODULE SEND BUFFER
%MW9.
623
%MW9.
624 Address 7: I/O MODULE SEND BUFFER
%MW9.
639
%MW9.
640 Address 8: I/O MODULE SEND BUFFER
%MW9.
655
%MW9.
656 Address 9: I/O MODULE SEND BUFFER
%MW9.
671
%MW9.
672 Address 10: I/O MODULE SEND BUFFER
%MW9.
687
%MW9.
688 Address 11: I/O MODULE SEND BUFFER
%MW9.
703
%MW9.
704 Address 12: I/O MODULE SEND BUFFER
%MW9.
719
%MW9.
720 Address 13: I/O MODULE SEND BUFFER
%MW9.
735
%MW9.
736 Address 14: I/O MODULE SEND BUFFER
%MW9.
751
%MW9.
752 Address 15: I/O MODULE SEND BUFFER
%MW9.
767
1.7 Software Functions
Description
Transmission header
Type code
I/O data
FCS
1
R/W
R
R
R/W
R/W
R/W
R/W
R
R
47

Hide quick links: