Trigger
4. For each value of HIL in table, verify that the DVM reading is
within the specified limits.
5. Record your results on a copy of the Test Record , specified limits
are given here and on the Test Record.
6. Set up the HP 8 1 12A as follows:
DEL
HIL
101
7. For each value of LOL in table, verify that the DVM reading is
within the specified limits.
8. Record your results on a copy of the Test Record, specified limits
are given here and on the Test Record.
Specification for 101/HIL
Note
EXT
HP3458A Reading
HP 81 12A
setting
Low Limit High Limit
HIL
0.056 v
0 . 1 v
0.5 v
0.44 v
0.92 v
1.0 v
5.0 v
4.76 v
8.0 v
7.64 v
65 ns
0.0 v
-0.10 v
HP 81 12A
DVM Reading
setting
LOL
Low Limit High Limit
-0.1 v
-0.056 v
-0.5 v
-0.44 v
-0.92 v
- 1 .0 v
-5.0 v
-4.76 v
-8.0 v
-7.64 v
=
0 V is ±40 m V, ±33 of amplitude.
0. 144 v
0.56 v
1 .08 v
5.24 v
8.36 v
-0. 144 v
-0.56 v
- 1 .08 v
-5.24 v
-8.36 v
Testing Performance 8-13