Specifi C Ations - HP 8112A Operating, Programming And Servicing Manual

50 mhz programmable pulse generator
Table of Contents

Advertisement

Delay Performance
Test
Specifications
Equipment
8·4
Testing Performance
the Test Record, specified limits are given here and on the Test
Record.
Range
75 ns to 950 ms
Accuracy
±53 of programmed value ±5 ns
Max Delay
period plus ( +) 55 ns
1
Repeatability
Factor 4 better than accuracy
Max Jitter
0.2% of programmed value ±lOOps
Counter (HP 5335A)
Two cable assembly BNC (same length)
50 n Feedthrough Termination
(Required if counter input impedance :f: 50
Collll t er reading
HP 81 12A
setting
PER
Low Limit High Limit
ns
ns
20
17.0
µs
µs
10
9.5
ms
ms
10
9.5
ms
950 ms
902.5
ns
23.0
µs
10.5
ms
10.5
ms
997.5
11)

Hide quick links: