Maintaining and servicing your device

6.1

General information on maintenance and servicing

Observe the following when servicing and repairing protective equipment e.g. such as
ground circuits or overvoltage protection components:
● Observe the maintenance and replacement intervals.
● Replace system components, including external cables, fuses and batteries only with
equivalent components approved by the respective manufacturer.
6.2

Cleaning the device

Note
When dust has collected on the device, the dust deposits must be removed at appropriate
time intervals.
Cleaning the IFP
Cleaning agents
Use dish soap or foaming screen cleaner only as cleaning agents. Built-in units may only be
cleaned at the front with cleaning agents.
NOTICE
Damage to the device due to impermissible cleaning agents
Impermissible and unsuitable cleaning agents can cause damage the device.
Use dish soap or foaming screen cleaner only as cleaning agents. Do not use the following
cleaning agents:
• Aggressive solvents or scouring powder
• Steam jets
• Compressed air
Observe the information on chemical resistance in section "Notes about usage (Page 30)".
Procedure
1. Switch off the device.
2. Dampen the cleaning cloth.
3. Spray the cleaning agent on the cloth and not directly on the device.
4. Clean the device with the cleaning cloth.
IFP V2, IFP V2 PRO
Operating Instructions, 08/2019, A5E46641410-AA
6