Configuration of the system

4.15 Configuring the SITOP UPS module for use with the PCU Base Software

4.15
Configuring the SITOP UPS module for use with the PCU Base
Software
4.15.1

Overview of SITOP UPS

SITOP UPS modules can continue operation of the SIEMENS PC system temporarily if a power
failure occurs and/or shut down the system correctly.
For example, a SITOP UPS module also protects against data loss when the SIEMENS PC
system hardware is shut down, because for technical reasons with Windows-based systems,
data is still written to the SSD after shutdown.
● You will find general information about SITOP UPS modules used in combination with the
PCU base software in Chapter SITOP modules for the PCU 50.5 (Page 53).
● If you want to use a SITOP UPS module in combination with the PCU base software, you
must first adapt the settings of the SITOP software (Page 54).
● Optionally, you can adapt the delay time after which the HMI software will be forced to shut
down (Page 57).
● You must configure the hardware (Page 60) of the SITOP UPS module before using it with
the PCU base software.
NOTICE
Ensure the readiness for operation of the SITOP power supply
In order to prevent data loss, the SITOP power supply must be ready for operation. Note the
following:
● The SITOP power supply may not be ready for operation immediately after being switched
● The operating system and the SITOP software must have run up so that the SITOP
● The readiness for operation and the functional capability of the SITOP power supply must
● Please also note all the information on the readiness for operation in the documentation
Further information
Information on the use of SITOP UPS modules in combination with the PCU base software
can also be found on the Internet:
● Service & Support Portal: SINUMERIK PCU 50.5: Use of an uninterruptible power supply
(http://support.automation.siemens.com/WW/view/en/90142681)
● Service & Support Portal: Typical values for an operator station with PCU 50.5 Windows 7
(http://support.automation.siemens.com/WW/view/en/76773241)
● SITOP Selection Tool (http://www.siemens.com/sitop-selection-tool) (Tool for the selection
of a SITOP UPS module)
52
on (a capacitor-buffered UPS500 requires 1-2 minutes make time, for example).
software can shut down the system correctly when a power failure occurs.
be ensured (e.g. battery of capacitor charged).
of your SITOP device.
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
PCU Base Software (IM10)