Configuration of the system

4.10 Set the resolution in the tcu.ini

4.10
Set the resolution in the tcu.ini
Overview
The system behavior during run-up for the screen resolution is set in the tcu.ini file in
Section [VNCServer].
You will find a template of the tcu.ini under C:\ProgramData\Siemens\Motion
Control\siemens\System\etc\
Do not overwrite this template, but rather create your own tcu.ini inside one of the user
directories (see Chapter Directory structure and file conventions (Page 14)).
Further information
● Chapter Directory structure and file conventions (Page 14).
● Operator Components Manual, Chapter "Networking"
Setting the resolution during power up of the PC system
The following options are available for selection in the tcu.ini file in the [VNCServer] section
(below the # RESOLUTION comment):
0 = SYSTEM
1 = AUTO_OP_1 (default)
2 = AUTO_OP_2
3 = AUTO_MON_1
4 = AUTO_MON_2
5 = 640x480
6 = 800x600
7 = 1024x768
8 = 1280x1024
9 = 800x480
10 = 1280x800
11 = 1366x768
12 = 1920x1080
38
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
PCU Base Software (IM10)