Drive Cliq Components; Application - Siemens NCU 7 0.2 Series Manual

Table of Contents

Advertisement

Connecting

7.5 DRIVE CLiQ components

Use flexible cables with a cross section of 0.25 to 2.5 mm
the power supply.
If you only use one wire per connection, a ferrule is not required.
You can use ferrules without an insulating collar in accordance with DIN 46228, Form A long
version.
7.5
DRIVE CLiQ components
7.5.1

Application

The components of the SINAMICS S120 drive family and the Control Unit are interconnected
using DRIVE-CLiQ. When connecting the components, please follow the rules in the
documentation below without exception:
The "Connecting components" section of the "Machine Configuration Guidelines" System
Manual
Properties
● Automatic detection of components
● 24 V/450 mA per DRIVE CLiQ interface is provided for the connection of encoders and
DRIVE-CliQ pin assignment
Table 7- 6
PIN
1
2
3
4
5
6
7
8
A
B
Signal type: I = Input; O = Output; VO = Voltage Output
52
measuring systems
DRIVE-CLiQ interface (X100 - X103 or X100 - X105)
Signal name
Signal type
TXP
O
TXN
O
RXP
I
RXN
I
+ (24 V)
VO
G (0 V)
VO
2
Meaning
Transmit data +
Transmit data -
Receive data +
Reserved, do not use
Reserved, do not use
Receive data -
Reserved, do not use
Reserved, do not use
Voltage supply for DRIVE-CLiQ, 450 mA maximum
Ground to 24 V
(or AWG 23 to AWG 13) for wiring
Manual, 02/2011, 6FC5397-0AP20-0BA0