Interface overview
Table 7- 1
Interface
DRIVE-CLiQ (1)
DRIVE-CLiQ (2)
DRIVE-CLiQ (3)
DRIVE-CLiQ (4)
DRIVE-CLiQ (5)
DRIVE-CLiQ (6)
Ethernet IE1/OP
Ethernet IE2/NET
Ethernet (service socket)
PROFINET
Digital inputs/outputs
24 V power supply
USB interfaces
PROFIBUS DP1
PROFIBUS DP2/MPI
RS232
Measuring sockets (T0, T1, T2,
and G)
CompactFlash Card
Dual fan/battery module
7.2

Safety information for wiring

Note the following:
Safety information
The system power supply must be disconnected when you wire the control unit.
NOTICE
If your axis grouping contains a Smart Line Module without DRIVE-CliQ (5 kW or 10 kW),
you must assign the Smart Line Module enable signal to digital output X122.1 on the
control unit.
NCU 7x0.2
Manual, 02/2011, 6FC5397-0AP20-0BA0
Overview of available external interfaces
DANGER
Designation
X100
X101
X102
X103
X104 (only NCU 720/730)
X105 (only NCU 720/730)
X120
X130
X127
Port 1 (only "PN NCUs")
Port 2 (only "PN NCUs")
X122, X132
X124
X125, X135
X126
X136
X140
X131 - X134
X109
X190
Connecting
7.2 Safety information for wiring
Connector type
Spec. RJ45 socket
Spec. RJ45 socket
Spec. RJ45 socket
Spec. RJ45 socket
Spec. RJ45 socket
Spec. RJ45 socket
Standard RJ45 socket
Standard RJ45 socket
Standard RJ45 socket
Standard RJ45 socket
Standard RJ45 socket
Screw terminals, 2x12-pin
Screw terminals, 4-pin
USB socket
9-pin SUB-D socket
9-pin SUB-D socket
9-pin SUB D plug connector
Sockets on the printed-circuit
board
50-pin socket
6-pin