Users Fail To Log In To The Server From The N2000 Bms Client Because Of The Incorrect Setting Of The Client - Huawei MA5600 Manual

Access network product cases
Table of Contents

Advertisement

MSAN UA5000 Cases
Check the optical splitter. It is found that the fiber in the inbound direction and the fiber in
the outbound direction are both connected to the ingress of the optical splitter.
Connect the fiber in the outbound direction to the egress of the optical splitter. The
problem is solved.
4. The optical splitter has two ingresses, an active one and a standby one. The fibers in
the inbound and outbound directions must be connected to the corresponding ports. The
incorrect connection causes large optical attenuation, thus affecting the service.
Suggestions and
When the ONT goes offline frequently, query the alarms and the performance statistics
Summary:
of the port to find the cause. Then, check the optical path segment by segment to locate
the fault.
3.16 Users Fail to Log In to the Server from the N2000 BMS Client Because of the Incorrect
Setting of the Client
Users Fail to Log In to the Server from the N2000 BMS Client Because of the
Title:
Incorrect Setting of the Client
ID: SE0000364646
Information
Troubleshooting Cases
Type :
Product Family: Optical Access
Fault Type: Host/Network Management System (independent from service)
Keywords: GPON, N2000 BMS
Permission
02Huawei Partners Permission
Level:
Phenomenon De
The N2000 BMS client can ping the server, and can automatically update the version
scription:
from the server, but fails to log in to the server, with the message "Communication fails"
displayed.
Alarm Informatio
When users log in to the server from the client, the system displays the message
n:
"Communication fails".
Cause Analysi
1. The version of the N2000 BMS on the server is not consistent with that on the client.
s:
2. The communication between the N2000 BMS server and the client fails.
3. The settings on the N2000 BMS server or client are incorrect.
Handling Proces
1. The client can ping the server, and automatically update the version from the server.
s:
Thus, the problem related to the communication is excluded.
2. Check the versions of the N2000 BMS server and client. It is found that the versions
are the same.
3. Check the "server settings" of the client. It is found that the mode is set to common.
Check the mode of the server, and it is found that the mode is set to SSL. Modify the
mode in the "server settings" on the client to "SSL". Then, users can log in to the server
from the client.
Suggestions and
The authentication mode of the server and the client of the N2000 BMS should be the
Summary:
same, "common" or "SSL".