Operation
6.8 Communication via PROFINET IO
Query commands
Get_Measurement_List_with_object
_number
Get_Measurement_Values
Get_Measurement_Values_with_obj
ect_number
6.8.4.5

PROFIenergy measured values

Table 6- 23
Overview of the PROFIenergy measured values
PROFIenergy measured
value
ID
Name
34
Active power
166
Power factor
200
Active energy
import
6.8.4.6
PROFIenergy energy-saving mode
The drive units support PROFIenergy energy-saving mode 2. The following two parameters
indicate the effective PROFIenergy mode:
● Parameter r5600 indicates the currently active PROFIenergy mode.
● Using interconnectable bits, the r5613 parameter indicates whether the PROFIenergy
energy saving is active.
Activating the energy saving mode
The energy-saving mode can activated or deactivated for the drive devices using the
PROFIenergy control commands (see also PROFIenergy commands).
266
PROFIenergy accuracy
Domain
Class
1
12
1
12
2
11
Description
This command returns the measured value IDs and the asso-
ciated object number that can be accessed using the
"Get_Measurement_Values_with_object_number" command.
The command returns the requested measured value using the
measured value ID:
For power measured values: The command addresses the
sum of the measured value over all control drive objects.
For energy measured values: The command returns the
sum of the measured value over all control drive objects.
For power factors: This measured value is supported only
for a SINAMICS with a control drive object.
This command returns the requested measured values using
the measured value ID and the object number. The object
number corresponds to the drive object ID.
The drive object ID of the Control Unit is used to address the
measured values as with "Get_Measurement_Value".
Unit
SINAMICS source parameters
Parameters
Name
W
r0032
Active power
smoothed
1
r0038
Smoothed pow-
er factor
Wh
r0039[1]
Energy accept-
ed
Operating Instructions, 07/2016, A5E00331449A
Value range
Largest value for
r2004 of all drive
objects
0 ... 1
-
Inverter chassis units